Technical data

26 ATS Designers Guide
1.5.1.7 Photo ID
The TITAN system provides a fully integrated Photo ID solution, which allows creation of
user, guest or client identification cards with their photo. The photographs can be
captured from a camera video stream, or imported in digital format. The TITAN system
enables design and priming of any user card sets either with detailed information about
the company and user (taken from the database), or without.
1.5.1.8 Control panel network monitoring
The TITAN system can support up to 16 COM ports simultaneously. Each COM port can
support up to 16 ATS control panels. In total there can be 64 systems connected to the
TITAN software at the same time. Each control panel is an independent security system
that reports to a single TITAN system.
1.5.1.9 ATS8100UP – Update
The software is provided in two versions – full and update. That way users of older
versions of the software can easily extend their systems with new features. The UP
version has a full range of database tools, and can, if needed, update and repair existing
databases without the need to import them after finishing the update.
1.5.1.10 Licence
In Poland the TITAN software is distributed free of charge, and the associated royalties
are included in the price of the control panel modules necessary to use the system’s
functions. Nevertheless all licence provisions hold their power – see software appendix.
Table 1-26 Technical characteristics
Parameter Value
Windows OS( 95/98, NT, 2000 or XP
Processor: Pentium 166 or better
32 MB RAM
100 MB free hard drive space
System requirements:
CD-ROM drive and mouse
Maximum number of connected PC’s 1 (TITAN is single workstation software)
Maximum number of simultaneously
connected control panels
64
Maximum number of control panels in the
system:
1024
Maximum number of systems in the database: 9999 systems
Maximum number of printers: Dependant on the number of assigned ports
Communication ports in the PC: Serial ports installed in the system (max. 16)
Recommended connection cable for
ATS1801:
4-wire shielded RS232 data cable (not twisted pair)
Recommended cable for the inbuilt RS232
port:
ATS1630 (RS232 active cable)
Maximum wiring length for RS232: 15 metres