CS-175-275-575 Series LCD User Guide
98/482/EC Declaration (Applies to products that have CE mark attached) This equipment has been approved in accordance with Council Decision 98/482/EC for Pan-European single terminal connection to the public switched telephone network (PSTN). However, due to differences between the individual PSTNs provided in different countries, the approval does not, of itself, give an unconditional assurance of successful operation on every PSTN network termination point. Aritech is an Interlogix company.
Contents LCD keypad ........................................................... 4 Setting the keypad tone ..................................... 16 Preparing your system .......................................... 6 Setting the system clock ..................................... 17 Turning on your system ......................................... 7 Viewing zone status ........................................... 19 Turning off your system ........................................ 8 Viewing alarm memory ...
LCD keypad Power (green): When lit, the system is connected to the mains power. Stay: Press to arm perimeter protection when on the premises. Ready (green): When lit, the system is ready to be turned on. Away: Press to arm complete system when leaving the premises. Fire (red): When lit, the fire zone has been activated. Bypass: Press to bypass (exclude) a zone (or zones) in the event of a zone fault. LCD display: Messages. Navigation: Press to scroll through menu on LCD display.
LCD keypad (green). The power light is on if the system is aPower connected to the mains and if the battery is okay. The power light will flash if the system has a low battery condition or when the battery is not connected. The power light is off if the mains is cut. (green). The ready LED is on when the system is bReady ready to arm, and flashes when the system is ready to force arm. If the LED is off, the system cannot be armed, generally because there is a zone fault. Fire (red).
Preparing your system System Not Ready For help, press LCD Message: Your system is NOT ready to be turned on, doors or windows might be open. j or k S X Fault Zone X or User Action: Use the up/down arrow. X Bypass Zone X i S X Fault Bypass Zone X or @ S System Ready Type code to arm LCD Message: Zone information. User Action: Press the bypass key if you want to bypass (exclude) a zone, so you can arm part of your system. X Okay Zone X LCD Message: Zone information. User Action: Press #.
Turning on your system OPTION 1: Using the function keys (This feature must be programmed by the installer.) System Ready Type code to arm g S LCD Message: Your system is ready to be turned on. h S System Armed Zone(s) Bypassed or System Armed All Zones Secure User Action: For stay mode, push the stay button, for away mode push the away button. LCD Message: Your system is either protected partially or completely.
Turning off your system System Armed All Zones Secure e S System Ready Type code to arm LCD Message: Your system is turned on. User Action: Type your user code to turn off your system. LCD Message: Your system is ready to be turned on.
Turning off your system in case of alarm ALARM Zone X e S X Alarm Mem. Zone X @ S System Ready Type code to arm LCD Message: An alarm has occurred in zone X. User Action: Type your user code to turn off your system. LCD Message: The last alarm is shown on the LCD message for verification. User Action: Press # to leave this LCD message. LCD Message: Your system is ready to be turned on.
Bypassing (excluding) one or more zones System Not Ready For help, press LCD Message: Your system is NOT ready to be turned on. jk S User Action: Use the up/down arrow. 1 Okay Zone 1 LCD Message: Shows the state of the first zone. jk S 2 Okay Zone 2 or User Action: Use the up/down arrow. 2 Bypass Zone 2 User Action: Press the bypass key to toggle between ‘Okay’ and ‘Bypass’. i S 2 Bypass Zone 2 or @ S LCD Message: Zone information. 2 Okay Zone 2 LCD Message: Zone information.
Bypassing (excluding) one or more zones (continued) System Ready Type code to arm e S System Armed Zone(s) Bypassed LCD Message: Your system is ready to be turned on. User Action: Type your user code to turn on the system. LCD Message: Your system is turned on, but zones are bypassed (excluded) and not protected.
Life safety functions You must press and hold the keys for 2 seconds to activate these functions! FIRE &+“S MEDICAL ‘+§S PERSONAL ATTACK è+çS User action: Press keys 1 and 3 together for two seconds. FIRE. A fire alarm is started and a message is sent to the central station. User action: Press keys 4 and 6 together for two seconds. MEDICAL. A medical alert is sent to the central station. User action: Press keys 7 and 9 together for two seconds.
Resetting fire detectors ALARM fire alarm e S LCD Message: Alarm message after a fire alarm. User Action: Type your user code to turn the system off. 8 Alarm Mem. fire alarm @S User Action: Press # System Ready Type code to arm LCD Message: Your system is turned off, and the fire detector has been activated. $ èS User Action: Press * 7 in order to reset the fire alarm The smoke detector has been reset. This may take 10 seconds. The fire LED (red) will turn off.
Changing user codes System Ready Type code to arm $ (S Please Enter Your Code eS Enter 2 digit ID &!S or @S Enter new code 18 * * * * §(‘“ S LCD Message: The system is ready to be turned on. User Action: Press * 5. LCD Message: The system asks for a master user code. User Action: Enter your master user code. LCD Message: Enter the two digit ID for the new or existing user. User Action: Enter the user ID, for example 18, or # to cancel operation. LCD Message: Enter the new code for this user.
Deleting user codes System Ready Type code to arm $ (S LCD Message: The system is ready to be turned on. User Action: Press * 5. Please Enter Your Code LCD Message: The system asks for a master user code. e S User Action: Enter your master user code. Enter 2 digit ID &!S or @S ggggS LCD Message: Enter the two digit ID for the new or existing user. User Action: Enter the user ID, for example 18, or # to cancel operation. User Action: Press G four times to delete the current user.
Setting the keypad tone System Ready Type code to arm $à S Raise tone Lower tone j or k S @ S LCD Message: The system is ready for arming. User Action: Press * 0. LCD Message: You will hear the current tone. User Action: Use up/down arrow to adjust the keypad tone. User Action: Use # to accept the tone you like.
Setting the system clock System Ready Type code to arm LCD Message: The system is ready to be turned on. $çèS User Action: Press * 97. Please Enter Your Code LCD Message: The system asks for a user code. e S User Action: Enter your user code.
Setting the system clock (continued) Wed 16:09 29 November 01 j or k S LCD Message: Current date and time are shown. User Action: Use the up/down arrow to change the hour,then minutes, day of the week, day of the month, month and year. $ S User Action: After you have the correct value, press * to move to the next item in the list. System Ready Type code to arm LCD Message: After selecting the year, the system will bring you back to the first step.
Viewing zone status System Ready Type code to arm LCD Message: The system is ready to be turned on. $j S User Action: Press * and up arrow. 1 Okay Living room j or k S 2 Okay Bed room j or k S LCD Message: The first zone is shown. User Action: Use either up or down arrow to scroll. LCD Message: The second zone is shown. User Action: Use either up or down arrow to scroll. 3 Okay Front entrance LCD Message: The third zone is shown.
Viewing alarm memory System Ready Type code to arm $“ S LCD Message: The system is ready to be turned on. User Action: Press * 3. 3 Alarm Mem. Zone 3 LCD Message: The first alarm in memory is shown. j or k S User Action: Use either up or down arrow to scroll. 5 Alarm Mem. Zone 5 LCD Message: The second alarm in memory is shown. j or k S User Action: Use either up or down arrow to scroll. 6 Alarm Mem. Zone 6 LCD Message: The third alarm in memory is shown.
Reading the event log System Ready Type code to arm LCD Message: The system is ready to be turned on. $ çà S Event Date/Time User Action: Press * 90. Please Enter Your Code LCD Message: The system asks for a user code. e S User Action: Enter your user code. Open 5 9/25 17:32 User or zone P3* Partition jk S Close 5 9/25 17:32 @ S P2* LCD Message: User 5 has opened partition 3 at 17:32 on September 25th. User Action: Use up/down arrow to scroll through the events.
Adjusting viewing angle/brightness of the LCD (text display) System Ready Type code to arm $ ç& S LCD Message: The system is ready to be turned on. User Action: Press * 91. Please Enter Your Code LCD Message: The system asks for a user code. e S User Action: Enter your user code. Raise view Lower view J K j or k$ S Brighten Dim J K j or k$ S LCD Message: Change the viewing angle of the LCD. User Action: Use arrow keys to change followed by * to accept.
Service messages display Service Required Type *2 for help LCD Message: Please contact your installer. $é S User Action: Press * 2 to see what is causing the problem. Expansion box tamper LCD Message: This message represents a tamper of an expansion box or a keypad. @ S User Action: Press # to exit the menu.
Service messages display (continued) Control Over-current A short circuit of a control’s power supply has occurred. Control Ground fault A short to ground has been detected on a control circuit. Control Siren trouble Open circuit has occurred on the bell or siren circuit. Control Loss of time Your system has lost total power and needs the clock reset. Control Box tamper (Optional) The Box Tamper circuit has activated. Control Power trouble The mains power to your system is not on.
Service messages display (continued) Expansion Aux. comm. fail An auxiliary reporting device has failed to communicate. Expansion Siren trouble Open circuit has occurred on the bell or siren circuit of the expander. Expansion Power trouble The mains power to an expansion power supply is not on. Zone Tamper, Press * A zone is tampered. Press * to identify the tampered zone.
Glossary of terms Armed The security system is turned on. Away Mode Turns on all of the security system. Forced arming An option that allows the system to be armed with one or more zones open. When the system is ready to be force armed, the ready LED flashes. Zones that are not closed do not create an alarm. Central station Location which monitors the alarm data sent during an alarm report. Function Key A key dedicated for a particular task.
Glossary of terms (continued) Power LED When lit, the system is connected to the mains power. Ready LED When lit, the system is ready to be turned on. Stay Mode Turns on the perimeter protection part of the security system. Tamper If the security system is interfered with, a tamper is recorded. You should contact your installer. User code A four or six digit code used to arm or disarm the system. Zone An area protected by a group of one or more detection devices.
ISO 9001 Certified 14 5113 999-1