Installation Instructions

CS175-275-575-875 Installation Guide 131
Seg#1 (Circle numbers to program) Seg#2
1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8
26
Dial attempts for phone number
Seg#1 ARC reporting
8
Seg#2 Before Fail to Communicate
8
Seg#3 Voice/Pager/Siren Tone Dialing
8
27
Report method
0
28
Dialer abort delay (0-255 sec)
30
29
Listen in time
30
30
Download access code
1-2-7-8-0-0-0-0
31
Rings to answer download
0
32
Download control
Seg#1 (Circle numbers to program)
1
2
3
4
5
6
7
8
Enables two call answering machine defeat.
Reserved
Requires call back before downloading.
Shutdown control panel.
Lock out local programming.
Lock out communicator programming.
Lock out download section.
Enables call back at autotest interval.
33
Call back phone number
14-14-14-14-14-14-14-14-14-
14-14-14-14-14-14-14
34
Partition #1, feature selection
Seg#1
1
2
3
4
Quick Arm
Re-Exit
Auto Bypass
Silent Keypad Panic (7 + 9 double press)
5
6
7
8
Audible Keypad Panic
Auxiliary 1 (1 + 3 double press)
Auxiliary 2 (4 + 6 double press)
Multi Keypress Tamper
Seg#2
1
2
3
4
LED extinguish enable
Require user code for bypassing zones
Bypass sounder alert
Mains power/low battery sounder alert
5
6
7
8
Enables bypass toggle
Enables silent auto arm
Enables automatic instant
Enables Silent Exit always
Seg#3
1
2
3
4
Open/Close
Bypass
Restore
Trouble
5
6
7
8
Tamper
Cancel
Recent Closing
Exit Error
Seg#4
1
2
3
4
Reserved
On: a wireless zone, which is lost, generates
a Tamper alarm during armed state and fault
during disarmed state.
On: enables restoral of events as disarming.
On: allow arming with a wireless zone, which
is lost.
5
6
7
8
Reserved
Reserved
Reserved
Reserved
Seg# 5 Reserved
35 Entry/exit timers
Seg#1 (Entry Time #1)
30
Seg#2 (Exit Time #1)
60
Seg#3 (Entry Time #2)
30
Seg#4 (Exit Time #2)
60
Segments #5 and #6 Reserved