Installation Instructions

CS175-275-575-875 Installation Guide 157
LED extinguish
This feature extinguishes all LEDs on the keypad, except the Power LED,
after 60 seconds without a keypress. Pressing any numeric key lights all
LEDs.
See
Location 34
on page 65 for more information.
LED Lockout
This feature causes the LED Extinguish feature to require a code to illuminate
the LEDs.
Local programming
lockout
This feature disables programming of all locations or specified locations from
the keypad.
See
Location 32
on page 64 for more information.
Manual test
The CSx75 can be programmed to perform a bell and/or communicator test
when 4 is pressed while the system is in the disarmed state.
See Location 51 on page 70 for more information.
On-board zone disable
The eight zones on the CSx75 panel can be disabled in order to have a
completely wireless alarm system.
See
Location 51
on page 70 for more information.
Open zone
A zone that is not secure such as a protected door or window which has been
left open.
Partitions
The CSx75 can be partitioned into a maximum of eight separate systems with
distinct reporting codes, user codes and operating features for each system.
See
Location 36
to
Location 43
, starting on page 67, for more information.
Program code
The factory default for the Go to program code is 1278
when using a four-digit
code or, if the six-digit location is used, the default is 127800. The Go to
program code can also be used as an arm/disarm code. If used as an
arm/disarm code and open/close reports are sent, the user code is 255.
See
Location 55
on page 72 for more information.
Quick arm feature
The CSx75 has a one button quick arm feature which can be used to arm the
system by pressing the Exit key or the Stay key on the keypad. If closing
reports are sent, the user code is 98.
See
Location 34
on page 65 for more information.
Recent closing
If enabled, the CSx75 sends a recent closing report to the central station if an
alarm occurs within five minutes after the panel is armed. The user number
that armed the system is also sent.
See
Location 34
on page 65 for more information.
Re-exit
The CSx75 has the ability to restart the exit delay for a quick exit without
disarming the system by pressing the Exit key while the system is armed.
See
Location 34
on page 65 for more information.
Shutdown
This mode causes the keypads to turn off all LEDs (except the Power LED)
and not accept keypresses.
See
Location 32
on page 64 for more information.