Product Overview

K-5
Arlington
www.aifittings.com | Tel: (800)233-4717 | Fax: (570)562-0646 | Email: Sales@aifittings.com
IN BOX
DBVR131C
DBVR171
DUTCH
LAP
DBVR151
5/8” LAP
5/8”
DBVR141
1/2” LAP
1/2”
DBVR131
1/4” &
5/16” LAP
1/4
&
5/16
Siding Profiles
D
E
A
B
C
22 cu. in.
Using the siding profile adapter
plate as a template, cut hole in
existing siding. Pull wiring.
Apply caulk around edges of back
of adapter. Press onto siding.
Apply caulk to reverse side of
IN BOX flange.
Install NM cable connector and wire, then attach with provided
long screws. Trim excess caulk as needed. Install wiring device per
manufacturers instructions, Local and National Electrical Codes.
Attach adapter to siding with
provided short screws. Trim
excess caulk as needed.
CATALOG
NUMBER
UPC/DCI/NAED
MFG #018997
ORIENTATION/
COVER COLOR
SIDING
LAP SIZE
UNIT
PKG
STD
PKG
DIM
A
DIM
B
DIM
C
DIM
D
DIM
E
DBVR131C 14370 Vertical/Clear 1/4” or 5/16” 1 4 7.186 4.934 5.160 1.567 3.539
DBVR131W 14375 Vertical/White 1/4” or 5/16” 1 4 7.186 4.934 5.160 1.567 3.539
DBVR141C 14371 Vertical/Clear 1/2” 1 4 7.186 4.934 5.160 1.567 3.539
DBVR141W 14376 Vertical/White 1/2” 1 4 7.186 4.934 5.160 1.567 3.539
DBVR151C 14372 Vertical/Clear 5/8” 1 4 7.186 4.934 5.160 1.567 3.539
DBVR151W 14377 Vertical/White 5/8” 1 4 7.186 4.934 5.160 1.567 3.539
DBVR171C 14373 Vertical/Clear Dutch 1 4 7.186 4.934 5.160 1.567 3.539
DBVR171W 14378 Vertical/White Dutch 1 4 7.186 4.934 5.160 1.567 3.539
1 2a 2b
3a 3b
Scan For Video
WEATHERPROOF-IN-USE
EXTRA-DUTY
Low Profile IN BOX™ for Retrofit Siding Construction
Recessed electrical box with weatherproof-in-use extra-duty cover for existing siding
construction. Non-metallic cover and base. Accepts most single gang wiring devices and uses
standard indoor wall plates or a GFCI cover plate. Box and white cover are textured/paintable.
UV rated plastic for long outdoor life.
FEATURES AND BENEFITS
IN BOXs one-piece assembly replaces the installation of an electrical box, siding block, and bubble
cover assembly
Installs in the wall, so less of it shows outside
Install option: Cover is removable for easier device installation
• No gaskets required
*Add suffix “GC” to Catalog # when ordering in Canada, for example DBVR131CGC.
Replacement covers available on page K-17.
PATENTED. ADDITIONAL PATENTS PENDING.
Note: Meets 2015 CEC (Rule 26-702), NEMA 3R, 2017 NEC 406.9 (b);
Where a weatherproof-in-use cover is required for 15 or 20 AMP
receptacles installed outdoors.
IN BOX for retrofit siding
includes…
Box with weatherproof-in-use
extra-duty cover, installed bug
plugs, siding profile adapter
plate, (1) standard duplex and (1)
standard GFCI face plate, (2) sets
installation screws, (1) NM cable
connector, and (2) rolls of caulk.
INSTALLATION INSTRUCTIONS for Existing Siding
Bug Plugs ship
installed in all
IN BOX styles
to seal unused
cord hole
openings.
E170558
LR49636