Specifications
  Cortex-M3 / Cortex-M3 with ETM (AT420/AT425) 
 Date of Issue: 12-Nov-2008  ARM Errata Notice  Document Revision 2.0 
PR326-PRDC-009450 v2.0 
© Copyright ARM Limited 2008. All rights reserved.  Page 13 of 20 
Non Confidential 
 532314:  DWT CPI counter increments during sleep 
Status 
Affects:  product Cortex-M3, Cortex-M3 with ETM. 
Fault status:  Cat 3, Present in: r0p0,r1p0,r1p1,r1p1-00rel0,r1p1-01rel0, Fixed in r2p0-00rel0. 
Description 
The DWT contains a number of counters for the profiling of applications. The CPI counter is used to indicate the 
total number of clock cycles beyond the first cycle of each instruction. The counter is specified to not increment 
whilst the core is sleeping but for previous revisions it does increment. This results in sleep cycles being 
counted as program execution cycles. 
Conditions 
1.  The CPI counter in the DWT is enabled 
2.  Core sleeps during profiling 
Implications 
Profiling information could be calculated incorrectly if the following calculation is used: 
InstructionCount = CycleCount – (CPIcount+LSUcount+INTcount+SLEEPcount) + FOLDcount 
Workaround 
The number of sleep cycles given by SLEEPCNT can be subtracted from the CPI cycle count to obtain the 
correct CPI cycle information. Use the following equation: 
InstructionCount = CycleCount – (CPIcount+LSUcount+INTcount) + FOLDcount 