User Guide

Features
speciFications
ordering inFormation
GFL3000
Power Requirements: 12 VDC
Battery type : 12 V rechargeable (included)
9V NEDA (not included)
Power Output: 2400 or 3400 VDC selectable
Voltage Protection: 240VAC/400VDC
Weight: Transmitter 9lbs. with battery
A-Frame: 3 lbs.
Warranty: 12 Months
CAT NO.
GFL3000
GFL3000R
GFL3000AF
GFL3000T
GFL3000ST
DESCRIPTION
Complete Kit
Receiver
Receiving Frame
Transmitter/Carrycase
Ground Stake
QUANTITY
1
1
1
1
1
Rev. 3 48K-0209
The GFL3000 Ground Fault Locator is a new low cost locator for contractors and maintenance personnel.
Incorporating dual power output, the GFL3000 pinpoints ground faults where electrical voltage is being
lost to ground. The GFL3000 transmits a powerful charge that is tracked by the GFL3000 receiver. By
simply going in the direction of the analog needle kicks on the receiver, the exact spot of the fault can be
found. Simply connect the transmitter to ground and the wire to be analyzed and turn it on. Follow the
kicks with the receiver using the visual meter.
The GFL3000 oers features not previously available at this price point. The GFL3000 features both high
and low power capability and a simple reading on the battery power available.
Test Equipment Depot - 800.517.8431 - 99 Washington Street Melrose, MA 02176