Instructions / Assembly

These instructions will install AcoustAffix
Surface Mount panels (2012WH, 2012BL, 2012 field paintable) using any one of the
following three methods:
Armstrong All-in-one Self-stop Fastener (used for attaching panels direct to deck or to walls)
Armstrong Truss Mounting Kit (used for attaching panels to an open truss system)
Adhesive (used for attaching panels to concrete, plaster or drywall)
ADDITIONAL INSTALLATION COMPONENTS:
12' HD Drywall Main Beam Steel Furring Channel (alternate suspension – not sold by Armstrong)
QuickStix Uptight Clip (QSUTC) Wood Furring (alternate suspension – not sold by Armstrong)
1. GENERAL INFORMATION
1.1 Product Description
AcoustAffix Surface Mount panels for ceilings are 3/4" thick, available in nominal size of 2' x 4', and offer acoustical absorption
when installed in an exposed structure environment. Standard panels are available in Black, White, and a scrimmed panel with no
finish. The scrimmed panel can be painted post installation to directly match the deck.
Field paintable panels have square edges on all four sides. On factory painted panels the long edges of the panel are square and
the short edges are reverse tegular.
1.2 Safety
During the installation be certain that the work site is well ventilated, and avoid breathing dust. If high dust levels are anticipated
during installation such as with the use of power tools, use appropriate NIOSH designated dust respirator. All power cutting tools
must be equipped with dust collectors. Avoid contact with skin or eyes. Wear long-sleeve, loose-fitting clothes, gloves, and eye
protection.
1.3 Warranty
Failure to follow the Armstrong Ceilings recommended installation instructions in effect at the time of installation will void the
product and/or ceiling system warranty.
1.4 Surface Finish
AcoustAffix panels (Black and White only) feature a finished latex paint on the face and panel edges.
1.5 Storage & Handling
To avoid damage, the ceiling panels should be stored in a dry interior location in a flat position and should remain in cartons prior
to installation.
1.6 Site Conditions
Building areas to receive ceilings shall be free of construction dust and debris.
AcoustAffix panels with factory paint finish can be installed in conditions between 32° F (0° C) and 120° F (49° C) and in spaces
before the building is enclosed where HVAC systems are cycled or not operating.
AcoustAffix field paintable panels have standard humidity resistance and should be installed in areas where the building is
enclosed and the HVAC is continuously functioning.
These products are not recommended for exterior applications where standing water is present (such as pools), or where
moisture will come into direct contact with the ceiling.
1.7 HVAC Design & Operation, Temperature & Humidity Control
It is also necessary for the area to be enclosed and for the HVAC systems to be functioning and in continuous operations for the
life of the product. All wet work (plastering, concrete, etc.) must be complete and dry. AcoustAffix panels cannot be used in
exterior applications.
1.8 Cleaning/Maintenance
Use a clean, dry, soft, white cloth to wipe off any dust or fingerprints.