Instructions / Assembly

How to Install AcoustAffix
Surface Mount Ceiling Panels
10. FIELD PAINTING
Field Painting Specification Recommendation:
Sherwin-Williams
®
Product – Waterborne Acrylic Dryfall (B42W1) 50 GAL. Drums MPI# 118 (or substitute Alkali-based, flat latex
paints with similar properties)
Recommended Spread Rate per Coat –
Wet Mils: 3.5 – 5.0
Dry Mils: 1.5 – 2.0
Coverage: 336-450 sq. ft./gallon approximate (based on flat surface)
* If necessary, cross spray at a right angle. Armstrong Ceilings recommends post painting once the install is complete. Do not paint
panels prior to installation in the ceiling as damage/markings during installation may be visible once installed. Field painting may
alter acoustical and fire performance.
Surface Preparation
Surface must be clean, dry, and in sound condition. Remove all oil, dirt, grease, and other foreign material to ensure
adequate adhesion.
Application Conditions and Equipment
Consult paint manufacturer.
11. SPECIAL INSTALLATION CONSIDERATIONS
11.1 Sloped and Wall Installations
AcoustAffix
panels can be installed on any slope (up to vertical surfaces/wall) when following the rules below:
When DGS mains are installed on a wall, it is recommended that the mains run vertical up the wall.
When DGS mains are installed on a slope, it is recommended that the mains run parallel with the slope. If the panel layout
requires the DGS mains to run horizontally across a wall or perpendicular to a slope, the spacing of the support attachments
of the DGS to structure (QSUTC) must be no more than 48" O.C.
12. Seisimic Installations
Seismic installations of 3/4" thick AcoustAffix panels are to be handled per building code.
For additional information on installing suspended ceilings, please visit our website at ceilings.com or call Techline at
1-877-ARMSTRONG (276-7876).6).