Installation Guide

1
RESIDENTIAL USE ONLY
Product
Gauge
Adhesive
Comments
ROYELLE 0.046" (1.17 mm) Full Spread Seams - Double cut
S-235 or S-254
Seam treatment:
STRATAMAX VP
0.060" (1.52 mm) Full Spread Apply S-570 using S-564 Low
S-235 or S-254
Gloss Seam Coating Kit,
S-595 High Gloss Seam Coating Kit
or
S-761 Seam Adhesive
Installation:
Location: All grade levels
Pattern Match: Yes; do not reverse pieces of patterned material (TM edge to non-TM edge); pieces of non-
patterned material should be reversed (TM edge to TM edge)
Seam Method: Double-cut
Seam Treatment: Apply S-570 Seam Coating using the S-595 High Gloss Seam Coating Kit, S-564 Low Gloss
Seam Coating Kit or S-761 Seam Adhesive
Fitting
:
All methods
Suitable Substrates: All substrates listed below must be properly prepared. There may be certain exceptions and
special conditions for these substrates to be suitable for the Residential Felt-Backed Installation System. For more
information, please call Armstrong Customer Care at 1-800-233-3823 or visit www.floorexpert.com.
Concrete
Existing Resilient Floors
Approved Suspended Wood
Ceramic Tile, Terrazzo, Marble
Polymeric Poured (seamless) FloorsSteel, Stainless Steel, Aluminum, Lead, Copper, Brass, Bronze
NOTE: For wood subfloors and underlayments, the moisture content must be 13%, or less.
Do not install over:
Particleboard, waferboard, OSB or single-layer Sturd-I-Floor panels
Existing cushion-backed vinyl flooring
Carpet
Hardwood flooring that has been installed directly over concrete
Job Conditions/Preparation (for all installation options):
Resilient flooring should only be installed in temperature-controlled environments. It is necessary to maintain
a constant temperature before, during and after the installation. Therefore, the permanent or temporary
HVAC system must be in operation before the installation of resilient flooring. Portable heaters are not
recommended as they may not heat the room and subfloor sufficiently. Kerosene heaters should never be
used.
Felt-Backed Sheet Flooring Installation System