Installation Instructions

Commercial Luxury Vinyl Tile Flooring Installation System
Product Information
Product Information
Product
Gauge
Size
Adhesive
Natural Creations
0.125" (3.2 mm)
Various Sizes and Shapes
S-288, S-543*, Flip or S-240**
Parallel LVT
.080(2.0mm)
.100(2.5mm)
Various Sizes and
Shapes
S-288, S-543*, Flip or S-240**
*It is necessary to smooth out the adhesive trowel ridges using a medium nap paint roller.
** It is necessary to smooth out the adhesive trowel ridges using a 3/16" (4.8 mm) nap paint roller. The purpose of this is to create a uniform
application of the adhesive.
Note: When installing Natural Creations/PARALLEL LVT in areas subject to direct sunlight, topical moisture, temperature fluctuations, Armstrong
S-240 Epoxy Adhesive must be used.
Location: All grade levels
Fitting: End Joints should be staggered a minimum of 6" (15 cm) apart
General Information
General Information
Commercial LVT Installation Video
Flip Spray Adhesive Video
Precautions
Precautions
No additional information for this field.
Tools
Tools
No additional information for this field.
SubFloor & Substrates
Subfloors & Substrates
Suitable Substrates: All substrates listed below must be properly prepared and meet requirements discussed in the Subfloors and
Underlayments Section. There may be certain exceptions and special conditions for these substrates to be suitable for the Luxury Solid Vinyl
Flooring Installation System.
Concrete (on all grade levels)
Wood or Board-Type Underlayments Disclaimer
Polymeric poured (seamless) floors
Steel, Stainless Steel, Aluminum
Ceramic Tile, Terrazzo, Marble
Existing Resilient Sheet Flooring
Existing Vinyl Composition Tile(VCT) On-grade or Suspended Only
Jobsite Prep
Jobsite Preparation
Resilient flooring should only be installed in temperature-controlled environments. It is necessary to maintain a constant
temperature before, during and after the installation. Therefore, the permanent or temporary HVAC system must be in operation
before the installation of resilient flooring. Portable heaters are not recommended as they may not heat the room and subfloor
sufficiently. Kerosene heaters should never be used
Substrates must be dry, clean, smooth and free from paint, varnish, wax, oils, solvents and other foreign matter.
in renovation or remodel work, remove any existing adhesive residue* so that 100% of the overall area of the original substrate is
exposed.
Allow all flooring materials and adhesives to condition to the room temperature for a minimum of 48 hours before starting the
installation.
The area to receive the resilient flooring should be maintained at a minimum of 65°F (18°C) and a maximum of 100°F (38°C) for 48
hours before, during and for 48 hours after completion. When using S-240 Epoxy Adhesive the maximum room temperature
should not exceed 85°F (29°C).
During the service life of the floor, the temperature should never rise above 100°F (38°C) nor fall below 55°F (13°C). The
performance of the flooring material and adhesives can be adversely affected outside this temperature range.
Conduct calcium chloride tests and/or percent relative humidity tests. Bond tests should also be conducted for compatibility with the
substrate. Please refer to Subfloors and Underlayments - Resilient.
Radiant-heated substrates must not exceed a maximum surface temperature of 85°F (29°C).
Concrete floors should be tested for alkalinity. The allowable readings for the installation of Armstrong flooring are 5 to 9 on the pH
scale.
Use S-240 Epoxy Adhesive in areas where the product will be subjected to direct sunlight, topical moisture, concentrated static and