Troubleshooting guide

HC-6000 Repair Parts
41
Component Voltage Resistance Component Voltage Resistance
Fill Valve 24Vac 18
Ω
Fill Valve 24Vac 8.8
Ω
Drain Valve 24Vac 10
Ω
Drain Valve 24Vac 4.1
Ω
Contractor 24Vac 7-9
Ω
Thermocouple in Heating Elements - 0.51
Ω
Thermocouple in Heating Elements - 0.51
Ω
208, 240, 380V, 30/33, 5/40/45/50,3/60kW 240Vac 7.4-9.1
Ω
208Vac and 380Vac 3kW 220 Vac 46.0-48.6
Ω
380V 48/72kW 220Vac 5.2-6.3
Ω
240Vac and 380Vac 3kW 240 Vac 55-58
Ω
480V 48/72kW 277Vac 8.1-10.0
Ω
480Vac and 380Vac 3kW 277 Vac 72-78.2
Ω
600V 48/72kW 346Vac 12.8-15.7
Ω
600Vac and 380Vac 3kW 346 Vac 112.4-122.4
Ω
Power Transformer
208Vac and 380Vac15/30kW 220Vac 9.2-10.7
Ω
208Vac
18
Ω
across H1-H2
240Vac 15/30kW 240Vac 10.9-12.6
Ω
240Vac 21
Ω
across H1-H3
480Vac 15/30kW 277Vac 14.5-16.8
Ω
277Vac 24
Ω
across H1-H4
600Vac 15/30kW 346Vac 22.7-26.3
Ω
380Vac 40
Ω
across H1-H5
208Vac and 380Vac9/18kW 220Vac 15.3-17.7
Ω
480Vac 53
Ω
across H1H6
240Vac 9/18kW 240Vac 18.2-21.1
Ω
600Vac 97
Ω
across H1-H2
480Vac 9/18kW 277Vac 24.3-28.2
Ω
208Vac 1
Ω
across X1-X2
600Vac 9/18kW 346Vac 37.9-43.9
Ω
240Vac 1
Ω
across X1-X2
120Vac
13.6
Ω
across H1-H2
15.1
Ω
across H3-H4
277Vac 1
Ω
across X1-X2
208Vac 22
Ω
across H1-H2 380Vac 1
Ω
across X1-X2
240Vac 29
Ω
across H1-H2 480Vac 1
Ω
across X1-X2
380Vac 77
Ω
across H1-H2 600Vac 1
Ω
across X1-X4
480Vac 125
Ω
across H1-H2
600Vac 194
Ω
across H1-H2
Power Transformer
(secondary)
All
Voltage
0.6
Ω
across X1-X2
0.4
Ω
across X1-X2
Secondary Loop
Note:
All measurements should be made with the main power off and
the wires to the component being tested disconnected.
Resistance Value of 6100/6300 Components
Heating Elements
Power Transformer
Resistance Value of 6500-6700 Comoponents
Heating Elements
Primary Loop