4.2 Mounting the IVS
The following tools are needed to mount the IVS:
3 mm allen key
0.5 x 3.5 mm screw driver (first time installation only)
2.5 mm allen key
1.5 mm allen key
As there is a vertical connector between the CCD optic
module and the Inserter/Antiflicker Module, it is necessary
to take the view finder system off the ARRIFLEX 435
before the IVS is installed.
The CCD optic module is mounted on the right side of the
ARRIFLEX 435 view finder system:
Disconnect camera of all power supplies.
For the initial installation of the IVS on the ARRIFLEX 435 it
may be necessary to exchange the flange, which is mounted
on the view finder system of the ARRIFLEX 435. The IVS is
delivered with a modified flange that can hold the IVS as
well as other video-assists. This new flange remains on
the ARRIFLEX 435. Therefore it is not necessary to remove
it when the IVS is taken off.
Support the viewfinder system.
Do not touch optic surfaces.
a) Remove the view finder system by loosening the three
mounting screws §.
•3 screws