User Manual

188 Appendix
Interface error. Reboot. An internal data interface has a problem. If re-
booting does not solve the problem, contact the
ARRI service.
Fan error. Contact service. The fan module is not working properly. Either
install an SFM-1, or contact the ARRI service.
Fatal system error. Shut down
camera.
Camera has to be rebooted. If this error contin-
ues to occur, a hardware problem might be the
reason. Contact the ARRI service.
Sync clock out of range. The sync signal clock does not match the cam-
era setting. Make sure the settings match.
Syncing sensor Slave camera syncs to master camera. Wait
until message disappears before starting to
record.
Synced camera is not ready One of the slave cameras is not ready for
recording.
Software error. Reboot. A part of the camera software has stopped
functioning properly and requires a camera re-
boot.
Internal audio recording failed Audio recording on internal medium failed.
REC error. Reboot. Error in the recording module. Reboot camera.
Mirror shutter not calibrated ALEXA SXT Studio only.
Mirror shutter must be calibrated by ARRI ser-
vice.
Mirror shutter phase error ALEXA SXT Studio only.
Mirror shutter continuously not in phase with
sensor. If rebooting does not solve the problem,
contact ARRI service.
Mirror shutter: Cannot reach
sync speed
ALEXA SXT Studio only.
Mirror shutter continuously not reaching sync
speed. If rebooting does not solve the problem,
contact ARRI service.
If any error that requires rebooting occurs repeatedly, contact the ARRI service.
20.5 Dimensions and Weights
Dimensional drawings including weights information are attached to the end of
this document. A version with higher resolution can be downloaded from the ARRI