User Manual

44 Getting started
NOTICE
The titanium PL LDS mount with LBUS connector (K2.0003216) does not supply
LBUS functionality nor lens data via the LDS contacts when attached to the AMIRA.
5.1.7 Changing a lens
NOTICE
Protect the sensor: Always keep a lens or protective cap on the empty lens mount.
Change lenses in dry, dust-free environments only.
Never exceed the maximum lens dimensions.
Have every lens properly shimmed as prescribed by the manufacturer.
PL mount
1
2
Note: Please use a lens support system for PL lenses above 3 kg/6.6 lbs.
1. Observe maximum lens dimensions.
2. Unlock the lens mount counter-clockwise (1) and remove the lens or cap.
Note: Never touch the sensor.
3. You have the following options:
°
Mount the next lens and lock (2) the lens mount clockwise.
°
Or: Always cap and lock (2) an empty lens mount clockwise.