Fixture Menu
19
DATA (2)
The DATA indicator lights blue, when a valid DMX signal
is detected on the DMX-input.
FUNCT (3)
The FUNCT button has two functions:
• Normal operation: Switches between CCT and HSI
mode (only L7-C).
• Fixture menu open: Jump UP one menu level.
ENTER (4)
The ENTER button has three functions:
• Normal operation: Activate blinking arrow for calling up
MEM1 or MEM2.
• Fixture menu open: OPEN next menu level, or
• Confirm a setting.
+ / [up] (5)
The + / [up] button navigates the menu or increases a value.
Press the button long to activate the fast-run feature.
- / [down](6)
The - / [down] button navigates the menu or decreases a value.
Press the button long to activate the fast-run feature.
INTENSITY (9)
The rotary knob sets the intensity level.
CCT / HUE (10)
The rotary knob sets the color temperature (CCT) or the hue
(only L7-C in color mode).
GN / SAT (11)
The rotary knob sets the green/magenta saturation or the color
saturation (SAT, only L7-C in color mode).
MEMORY 1 and MEMORY 2 (7 and 8)
Activate or store a memory.
During operation the mode and recent values are displayed.
On the first menu level the values for INTENSITY, CCT/HUE
(only L7-C) and GN/SAT (only L7-C) can be retrieved via the +
/ [up]/- / [down] buttons. The menu STATUS, confirmed with
ENTER, calls up the next level which displays information on
faultless operation and the temperature of the light engine. To
retrieve values for operating hours, DMX-version and firmware-
version, press ENTER to call up the third level. The FUNCT
button jumps up one menu level.
A detailed overview of the fixture menu is listed in section
“Fixture Menu” on page 27.
To set the operation mode (only L7-C)
Press the FUNCT button to switch from CCT mode to HSI
mode and vice versa.
IN CCT mode the L7 generates white light with optimized color
rendition. In HSI mode the L7 generates colored light. If satu-
ration is set very low, the L7 generates white light, but not with
optimized color rendition.