User Manual

Error Messages
33
Error Messages
Code Error Remedy
E.003
Controller over temperature.
STATUS lit up red.
Let the product cool down. The STATUS indicator changes to green when the product has
cooled down. Turn the dimmer knob to „0“ or send an intensity value „0“ via DMX to acti-
vate the light engine again.
E.004 Light engine over temperature See E.003
E.005 Power supply over temperature See E.003
E.006
Calibration data of light engine
faulty or EEPROM error.
WARNING: Loss of calibration data. This error can only be fixed by re-calibrating the light
engine. Please contact the ARRI service.
E.007 Invalid PWM value calculation Notice: The product can be used on. This message is more a notification than an error.
E.008 Invalid values during calculation See E.007
E.009 Invalid values during calculation See E.007
E.010
Fan error. The fan speed devi-
ates or the fan doesn’t run at all.
Set the fan to LOW or HI and see if it starts rotating, in order to determine if there is an
electrical malfunction.
All mechanical tests or repairs may only be carried out by a trained service technician.
From SW version 1.72.0
E.011
Fixture menu module not be
detected.
If the fixture menu is working, error E.011 can be ignored. However, if the fixture menu
remains dark (no LED lights up) we recommend to contact the ARRI service. They can
then carry out detailed analyses.
E.012
Temperature sensor(s) are
defective or deviation within
NTC values too high.
One or more temperature sensors are defective or the deviation within the individual NTCs
or BNTCs exceeds the variation tolerance of 12° C / 54° F. Check the error log (LSeries
Manager) to see which temperature sensors are affected. Contact the ARRI service.