5.1.3 Setting the operating modes
Press the FUNCT key (17) brie y to switch from CCT mode to HSI mode or vice versa.
In CCT mode the lamphead generates White light with optimized color rendition CRI > 95.
In HSI mode the lamphead generates colored light. If saturation is set very low, the lamphead will generate White light, but with
optimized color rendition.
5.1.4 Setting the color temperature and Green-magenta adjustment in CCT mode
With the rotary knob CCT/HUE (22) the color temperature can be adjusted continuously.
The rotary knob GN/SAT (23) serves for continuous green-magenta adjustment.
You can retrieve the currently set value for Green-magenta adjustment by pressing the keys + (19) or - (20) repeatedly until GRN is
displayed on the left side of the display (e.g. +0.23). The setting for color temperature is always displayed (e.g. 4150K).
5.1.5 Setting the color in HSI mode
With the rotary knob CCT/HUE (22 ) you can adjust the value for hue continuously.
Use the rotary knob GN/SAT (23) for continuous adjustment of saturation.
You can retrieve the currently set value for saturation by pressing the keys + (19) or - (20) repeatedly until SAT is displayed on the
left side of the display (e.g. 45). The setting for hue is always displayed (e.g. 4118°).
5.1.6 Setting intensity in both operating modes
With the rotary knob INTENSITY (21) you can continuously adjust intensity in both operating modes. You can retrieve the currently
set value for intensity by pressing the keys + (19) or - (20) repeatedly until INTENSITY is displayed on the left side of the display
(e.g. 24%).
5.1.7 Setting the fan functions
You can set the different fan functions via the on-board control from menu level 3.
Proceed as follows:
Press the keys + (19) or - (20) repeatedly until SETUP is displayed in the left lower corner of the display (27).
Con rm with the ENTER key (18). Press the key + (19) or - (20) repeatedly until FAN is shown in the display (27). Con rm with
ENTER (18) again. The currently used fan mode is displayed.
By pressing the keys + (19) or - (20) you can select the desired fan mode (see table below). Con rm your selection with the ENTER
key (18). The fan will now work in the desired mode. Press the FUNCT key (17) twice to leave this menu level.
5.1.8 Setting the DMX address
Go to menu level 4 to set the DMX start address via the on-board control.
Proceed as follows:
Press the keys + (19) or - (20) repeatedly until SETUP is displayed in the left lower corner of the display (27).
Con rm with the ENTER key (18). Press the key + (19) or - (20) repeatedly until DMX is shown in the display (27). Con rm with
ENTER (18) again. Press the key + (19) or - (20) repeatedly until CHAN is shown in the display (27). When you press the ENTER
key now the currently used DMX start address is displayed. Use the keys + (19) or - (20) to select a value from C.001 to C.506 an
con rm your selection with the ENTER key (18). The DMX start address is now set. Press the FUNCT key (17) three times to leave
this menu level.
Fan mode L7 Hybrid L7 Active L7-T4 Description of mode
OFF x Fan is turned off, it may occur that the lamphead turnes itself off due to
overheating. Once the lamphead has cooled down it can be turned on and
used again.
LOW x x Fan operates constantly at low speed (silent)
HI x Fan operates constantly at maximum speed
A-LOW x Fan operates from 80% intensity with 1050 rev/min
A-HI x Fan operates from 80% intensity with maximum speed
VARI x x Fan is controlled via the light-engine temperature, fan starts at approx.
70°C / 158° F, steps speed up or down automatically
PASS x No fan, light output is reduced by 20%
HI 45 x Optimized for an ambient temperature of 45°C / 113° F, fan operates at
max. speed, light output is reduced by approx 15%