Manufacturer commands
Command (English) Description GET SET
RDM Fan Mode
PID:0x8001
Changes the FAN mode of the xture
- this message supports Set and Get commands
- the rst data byte is used to show / change the fan mode
USER_FAN_MODE_OFF = 0
USER_FAN_MODE_LOW = 1
USER_FAN_MODE_HIGH = 2
USER_FAN_MODE_AUTO_LOW = 3
USER_FAN_MODE_AUTO_HIGH = 4
RDM Status LED
PID:0x8002
Switch on /off indication LEDs and LCD back light
- this message supports Set and Get commands
- the rst data byte is used to switch indication LEDs on and off
LEDs and LCD back light on = 0
LEDs and LCD back light off = 1
Supported from SW-Version 1.72.0, only L7-T4
RDM L7T4CH CCT
ADJ
PID:0x8003
CCT value, the CCT value can be used to do some settings manu-
ally
yes yes
Supported values from 2600K - 10000K, only L7-T4
RDM L7T4CH GN ADJ
PID:0x8004
GN value, the GN value can be used to do some settings manually yes yes
Supported values from -1 to +1
RDM DMX Signal Lost
Mode
PID:0x8005
If the DMX signal gets lost or the DMX device is unplugged the
LED xture holds the last valid signal, or it holds the last valid sig-
nal for two minutes and then dimms or switches off immediately.
Supported values:
0 -> hold
1 -> hold 2 minutes
3 -> switch off
yes yes