Photometric data
Distance 3 m / 9.8 ft 5 m / 16.4 ft 7 m / 23.0 ft 9 m / 29.5 ft
L7-C, 3200 K
Spot: 15° 4570 lx / 430 fc 1650 lx / 154 fc 840 lx / 79 fc 508 lx / 48 fc
Middle: 30° 1370 lx / 128 fc 492 lx / 46 fc 251 lx / 23 fc 152 lx / 14 fc
Flood: 50° 596 lx / 56 fc 214 lx / 20 fc 109 lx / 10 fc 66 lx / 6 fc
L7-C, 5600 K
Spot: 15° 5180 lx / 484 fc 1870 lx / 174 fc 951 lx / 89 fc 576 lx / 54 fc
Middle: 30° 1550 lx / 144 fc 556 lx / 52 fc 283 lx / 26 fc 171 lx / 16 fc
Flood: 50° 668 lx / 62 fc 240 lx / 22 fc 123 lx / 11 fc 74 lx / 7 fc
L7-T 3200 K
Spot: 15° 6157 lx / 572 fc 2217 lx / 206 fc 1131 lx / 105 fc 684 lx / 64 fc
Middle: 30° 1806 lx / 168 fc 650 lx / 60 fc 332 lx / 31 fc 201 lx / 19 fc
Flood: 50° 747 lx / 69 fc 269 lx / 25 fc 137 lx / 13 fc 83 lx / 8 fc
Photometric values valid for L7 hybrid and L7 aktiv at an ambient temperature up to 35°C / 95°F.
Photometric values of L7 aktiv will be reduced by 20% at ambient temperatures higher than 35°C / 95°F.
Individual specifi cations
Lamphead type L7-C hybrid L7-T hybrid L7-C aktiv L7-T aktiv
Weight 10.9 kg / 24 lb (hanging /
stand), 12.5 kg / 27 lb (pole
operation)
10.9 kg / 24 lb (hanging /
stand), 12.5 kg / 27 lb (pole
operation)
8.2 kg / 18 lb (hanging /
stand), 9.8 kg / 21.6 lb (pole
operation)
8.2 kg / 18 lb (hanging /
stand), 9.8 kg / 21.6 lb (pole
operation)
White light Continuously variable corre-
lated color temperature from
2,800 K - 10,000 K
3,200 K Continuously variable corre-
lated color temperature from
2,800 K - 10,000 K
3200 K
Colored light Full RGB+W gamut with hue
and saturation control
- Full RGB+W gamut with hue
and saturation control
-
Color rendition CRI 95 (3,200 K - 6,500 K) - CRI 95 (3,200 K - 6,500 K) -
Green-Magenta adjustment Continuously adjustable +/- 1/8 (nominal) Continuously adjustable +/- 1/8 (nominal)
Ambient temperature opertion 0° - 35° C / 32° - 95° F 0° - 35° C / 32° - 95° F 0° - 45° C / 32° - 113° F 0° - 45° C / 32° - 113° F
Protection class IP 20 (optional IP 23) IP 20 (optional IP 23) IP 20 (optional IP 23) IP 20 (optional IP 23)
Applications regular studios regular studios small studios / location small studios / location
All specifi cations are nominal / typical values.