FEM-2 Instruction Manual As of: 05/2003 ALL THEY MUST NOT BE COPIED (E.G. ON IF CD-ROM, YOU ARE DOWNLOADING WE PDF-FILES ARTWORK, PICTURES AND TEXTS ARE COVERED BY OUR COPYRIGHT. DISKS OR INTERNET-SITES) OR USED IN THEIR ENTIRE FORM OR IN EXCERPTS WITHOUT OUR PREVIOUS WRITTEN AGREEMENT. FROM OUR INTERNET HOMEPAGE FOR YOUR PERSONAL USE, MAKE SURE TO CHECK FOR UPDATED VERSIONS. CANNOT TAKE ANY LIABILITY WHATSOEVER FOR DOWNLOADED FILES, AS TECHNICAL DATA ARE SUBJECT TO CHANGE WITHOUT NOTICE.
Contents
1. Contents .......................................................3 2. Safety Instructions and Legal Disclaimer ..5 2.1. Safety Instructions .........................................5 Warning Signs .............................................5 General Safety Instructions .............................5 Product Specifications....................................6 Explanation of the Symbols in the Manual........6 2.2 Disclaimer....................................................7 3. General Description ......
Contents 4 5.4 5.5 Camera remote control ................................33 WRC-1 via wireless remote control................34 WRC-1 with WHA-2 via cable .....................35 WRC-1 with WHA-1 ...................................36 RCU-1 .......................................................37 CCU-1.......................................................38 Time code ..................................................39 Operation..................................................
2.1. Safety Instructions Please always follow these instructions to help ensure against injury to yourself and damage to the system or other objects. This safety information is additional to the product-specific operating instructions in general and must be strictly observed for safety reasons. They are no substitute to settled down you own safety measures. Warning Signs Possible risk of injury or damage to equipment.
Disclaimer Do not operate the system in high humidity areas or expose it to water or moisture. Do not place the system on an unstable cart, stand, tripod, bracket, or table. The system may fall, causing serious personal injury and damage to the system or other objects. Operate the system using only the type of power source indicated in the manual. Unplug the power cord by gripping the power plug, not the cord.
No part of this document may be copied or reproduced in any form or by any means without prior written consent of ARRI. ARRI assumes no responsibility for any errors that may appear in this document. The information is subject to change without notice. For actual design-in, refer to the latest publications of ARRI data sheets or data books, etc., for the most up-to-date specifications. Not all products and/or types are available in every country.
Disclaimer 8 of any material or goods associated with the assembly or use of our products, or any other damages or injury of persons and so on or under any other legal theory. In the case one or all of the forgoing clauses are not allowed by applicable law, the fullest extent permissible clauses by applicable law are validated. ARRI is a registered trademark of Arnold & Richter Cine Technik GmbH & Co Betriebs KG.
The FEM-2 is an expansion module for the ARRIFLEX 435 Advanced camera that provides the following functions: • LDD (Lens Data Display) interface • CCU interface (RS232) • ACC interface • Time code exposure according to SMPTE RP136 (Barcode) • Controls up to three CLM-2 motors • Two LCS bus interfaces for CLM-1, WHA-2 and ZMU-1 • URM-1 (Universal Radio Module) compatible Compatibility To use the FEM-2 with the ARRIFLEX 435 Advanced the following Versions of Software are necessary: 435 Advanced: SW 2.
The System The FEM-2 is compatible with the following cameras and accessories: Cameras ARRIFLEX 435 Advanced ......................................................... K0.59981.0 ARRIFLEX 435 Advanced Anamorphic ....................................... K0.59982.0 ARRIFLEX 435 Advanced 3perf................................................. K0.59983.0 Lens Control URM-1 ................................................................................... K2.52048.0 RCU-1........................................
Use of the following equipment is not permitted! UC-C2 Run Cable .....................................................................K2.52076.0 LC-S1 Power Cable ...................................................................K4.46859.0 LC-S2 Power Cable ...................................................................K2.47146.0 The System Use of the following equipment is not permitted LC-S3 Power Cable ...................................................................K2.47147.
Installation and Setup
Switch off the camera and disconnect all cables from the camera and the FEM-2 before installing the FEM-2 on the camera. Switch off the camera and disconnect all cables from the camera and the FEM-2 before installing the URM-1 on the camera. The installation of the FEM-2 and the URM-1 has to be carried out on a static free workstation. Preparation • Verify the software version of the camera before installation: Software version 3.xx or higher is required to operate the FEM-2 with the ARRIFLEX 435 Advanced.
Installation and Setup guidings fastening flaps fastening screw 14
Install the FEM-2 on the right side of the camera. Installation must be carried out at an ESDsecured workstation. To install the device: • The camera should be fixed ideally on a pivoting head to secure working. • Turn the camera off and disconnect all cables. • Remove the screw on the FEM-1 that is installed on the right side of the camera photo. • Pull the FEM-1 backwards to remove it from the camera. • Insert the two tabs at the front of the FEM-2 into the guiding on the camera (or IVS) photo.
Installation and Setup cover two screws M3x8 A2 DIN 912 16
• Untighten the two screws cover. photo and remove the • Remove the two screws (DIN 912 M3*8) from the holes in the cover. • Apply the URM-1 to the FEM-2. • Secure the URM-1 to the FEM-2 using the two screws taken from the cover (tightening torque<0.3Nm). Insert and tighten screws here Installation and Setup 4.
Operating Lens motor status LED LDD socket CLM-2 plug-in module Direction selection switch Radio Status RDY-LED Channel selection switch LCS bus sockets ACC socket CCU LED CCU socket Battery compartment for time code clock 18 LDS-Status LED for CLM-2 motors URM-1 module
5.1 Lens Data Display The LDS integrated into the FEM-2 is compatible with all lenses equipped with ARRI LDS contacts. The LDS status LED photo indicates the status of the LDS system as follows: Color Status Green LDS OK Off No LDS lens Red LDS transfer error • The lens data display is connected to the LDD socket photo on the top of the module. The following cables should be used: Operating 5. Operating LDD K4.55855.0 LDD cable 0.5m / 1.7 ft Spiral Cable LDD-FP K2.54172.0 LDD-FP cable 0.
Operating LDS status LED Radio status RDY-LED cannel selection URM-1 module 20
Select an RF channel indicated for use in your country before switching on the system. Do not use RF channels that are not permitted in your country. Only use antennas supplied by ARRI. Do not use directional antennas, omni-directional antennas or boosters. The RF modem could be damaged and conformance to standards cannot be ensured. A radio receiver URM-1 photo can be mounted on the FEM-2. This permits the wireless communication of positioning information for lenses and the camera remote control.
Operating To change the radio channel: • With the camera off, set the channel and then turn the camera on. • Set the channel selection switch to 9 (deactivated) and then turn it to the required channel within half a second. • Set the channel selection switch on the activated camera to the new channel, the RF LED goes red. Then turn the camera off and back on after around 5 seconds.
Operating 5.3 Remote Lens Control Lens Motors LCS-bus sockets Both CLM-1 and CLM-2 motors can be used with the FEM-2. • The CLM-1 motors are connected to the LCS bus sockets photo. • The CLM-2 motors should be connected to the zoom, focus and iris sockets photo on the CLM-2 plug-in module. Note: CLM-1 motor function has priority over the CLM-2 motor. If a CLM-1 motor is set to the function zoom, focus or iris and is connected to the FEM-2, the corresponding CLM-2 connection is deactivated.
Operating • Use the direction switch to change the rotational direction of the attached motor. The status LED indicates the following: The LC-M1, LC-M2, LC-Z1 and LC-Z2 cables are interchangeable and differ only in their appearance and length. Color Status Off no motor connected Red motor connected, but no handheld control found Cable Appearance Green motor OK LC-M1 Spiral, 1m long outstretched Green blinking motor OK, but in an end stop LC-M2 Straight, 0.
CLM-1 Zoom CLM-1 Focus LC-F2 LC-M1 LC-M2 Operating CLM-1 Iris ZMU-1, FIU-1 and CLM-1 Motors LC-M2 FIU Focus LC-F1 FIU Iris LC-Z1 ZMU 25
Operating CLM-2 Iris ZMU-1, FIU-1 and CLM-2 Motors LC-F2 FIU Focus LC-F1 FIU Iris 26 LC-Z1 ZMU CLM-2 Focus CLM-2 Zoom
WFU-1 WZU-1 WHA-2 LC-M1 CLM-1 Zoom LC-M2 CLM-1 Focus Operating CLM-1 Iris WFU-1, WZU-1 and WHA-2 mit CLM-1 Motors LC-M2 LC-Z1 27
WFU-1 WZU-1 WHA-2 Operating WFU-1, WZU-1 and WHA-2 mit CLM-2 Motors LC-Z1 28 CLM-2 Iris CLM-2 Focus CLM-2 Zoom
Mixed Operation LC-M1 CLM-1 Zoom LC-M2 WHA-2 WFU-1 Operating CLM-1 Focus LC-Z1 CLM-2 Iris LC-Z1 ZMU 29
Operating CLM-1 Focus Wireless Control of Focus and Iris, Zoom via ZMU-1 CLM-1 Zoom WMU-1 LC-M1 LC-M2 CLM-2 Iris LC-Z1 ZMU 30 WFU-1
WMU-1 WZU-1 CLM-2 Iris CLM-2 Focus CLM-2 Zoom Operating Zoom, Focus and Iris Wireless WFU-1 31
Operating CLM-1 Iris Zoom, Focus and Iris Wireless via Two Separate Handheld Controls LC-M1 WMU-1 32 WZU-1 WMU-1 WFU-1 CLM-1 Zoom LC-M2 CLM-1 Focus LC-M2
Note: For details of how to use the RCU-1 and WRC-1, please see the instruction manuals supplied with these units. For details of how to use RCU-1 and ESU-1, please see the instruction manual for the ARRIFLEX 435 Advanced. The FEM-2 enables the camera to be remote controlled by cable and via wireless remote control. Only one control unit may be connected to the FEM-2 at any time.
Operating WRC-1 via wireless remote control WRC-1 + WMU-1 34
Operating WRC-1 with WHA-2 via cable LC-M1 WRC-1 + WHA-2 35
Operating WRC-1 with WHA-1 WC-W1 WRC-1 + WHA-2 36
KC39 Operating RCU-1 RCU-1 37
Operating CCU-1 KC24S CCU-1 38
Check if the area for the time code (barcode) exposure at the edge of the film is outside of the image area defined by the used format mask. If the selected format mask does not cover the time code area, the time code will be exposed into the image area. Operation Note: Changing the batteries The batteries for the time code clock are located under a cover on the bottom of the FEM-2 photo. • Use a coin to screw open the battery compartment. Operating 5.
Technical Data 6. Technical Data Operating temperature .............. -20°C to + 50°C Operating voltage..................... As for the ARRIFLEX 435 Advanced Protection type.......................... IP 42 LDD plug.................................. For ARRI LDD or LDD-FP or ARRIMOTION LCB connection LCS bus ................................... 5pol as per ARRI standard Max 2.5 A on both sockets in total Compatible with WHA-2, ZMU-1 and CLM-1 CLM-2 connectors .....................
Instruction Manual for ARRIFLEX 435 Advanced.......................... K5.58231.0 Instruction Manual for the WRC-1 in German ............................. K5.43660.0 Instruction Manual for the WRC-1 in English ............................... K5.43668.0 Instruction Manual for the LCS in German .................................. K5.52422.0 Instruction Manual for the LCS in English .................................... K5.52423.0 Additional Documentations 7.