Operation
5.2.6 Trigger Function
The trigger function allows precisely timed activation of
recording or playback functions of selected ranges.
Operations like focusing on a moving object can be more
accurately reproduced when the adjustments of memory
module are activated by the trigger functions via a remote
activation signal.
5.2.6.1 Recording
• Select the desired memory bank.
• To initialize:
press the REC key ➪ photo
– the REC-LED will flash. The LCS is ready for recording.
This status can be cancelled by pressing the MEM key.
If no memory bank has been pre-selected, memory
bank LEDs 1 and 2 will flash. Select memory bank!
• To start recording:
connect the trigger contacts.
During recording, the REC-LED will be illuminated.
• To stop recording:
press the REC key again or wait until the entire
sequence has been recorded.
socket for Trigger contact