Operation
ICU-1 Connecting Cables
The ICU-1 identifies different camera models through
different cables.
The ICU-1 and the lens motor are generally powered from
the camera, but can also be connected to a separate 12 or
24 Volt battery (with cable LC-S1). The ICU-1 will auto-
matically detect if the incoming voltage is 12 or 24 Volts.
Note: If the camera runs on 12 V, it is recommended
to use a separate 24 Volt battery for the ICU-1.
The lens motor will be able to respond at a faster
rate when connected to a 24V power source.
Note: When powering the ICU-1 and the Motors from
the camera, make sure that the maximum load
of the used connector on the camera is not
exceeded
Make cable connections according to the diagram.
To power the ICU-1 from a separate battery, connect
cable LC-S1 to the battery and to the unused connector
on the lens motor.
Camera Camera Cable
ARRICAM ST/LT KC 72 cable to CAC receptable
Part number: K2.54137.0
ARRIFLEX 535 Connect LC-D1 to RU receptacle
535B Connect LC-D1 to ACC receptacle
16SR 3 Connect LC-D1 to ACC receptacle
16SR 3 HS Connect LC-D1 to ACC receptacle
435ES Connect LC-D1 to RU receptacle
435 Adv. Part number: K2.47029.0
ARRIFLEX 35 III Connect LC-D2 to 11 pin accessory receptacle
435 Part number: K2.47030.0
435ES
435 Adv.
ARRIFLEX 16SR Connect LC-D4 to 11 pin accessory receptacle
16SR II Part number: K2.47048.0
16SR II HS
ARRIFLEX 765 Connect LC-D3 to SCU receptacle
Part number: K2.47031.0