Instruction manual
  2  2.8  4  5.6  8  11  16
161
Operation
Assigning F-Stops with the ICU-1
The ICU-1 has to be taught where on the iris ring the F-Stops 
are. There are two different methods for two different 
types of iris scales:
•  A linear iris scale is an iris scale where each F-Stop is 
exactly the same distance from the next one. Zeiss 
Standard Primes, Super Speed Primes and Variable 
Primes have a linear iris scale, for example. Assigning 
F-Stops for a linear iris scale is a one step procedure.
•  A non-linear iris scale is an iris scale where the 
distances between the F-Stops differ. The Angenieux 
25-250HR has a non-linear iris scale, for example. 
Each F-Stop will have to be assigned individually for a 
non-linear iris scale.
SET F-STOP-LED 
NON LINEAR-LED
CAL key 
F-STOP key
OPEN key
CLOSE key
linear iris scale 
  start here  end here