Mechanical Acessories
• Push the tube ø 15mm flush into the diminishing tube
on the console. Ensure that the slit ➪ photo in the
tube points in the direction of the ballcatch.
• Screw the ballcatch out of the bracket until the tube
can no longer be pushed out of the bracket.
• Turn the locking lever until a slight resistance can be
felt, then press the lever downwards.
• Flip up the clamp brackets.
• Place the diminishing brackets into the clamp brackets.
• Secure the diminishing brackets with two screws each
on the exterior.
Order number for the console: K2.52035.0
diminishing tube
locking lever tube
ballcatch
socket