Instruction manual

182
Trouble-Shooting
7.2 UMC, LDB, FEM-2 Motor Controller LEDs
Problem Cause Remedy
READY LED illuminated red Operating error on the UMC/LDB/FEM-2 go back to prior status
(radio channel was altered while switched on,
an attempt was made to switch off the UMC/LDB/FEM-2
while the camera was running)
READY LED flashes red URM with same radio channel active select another radio channel
Motor LED illuminated red ZMU or WMU is switched off switch on ZMU or WMU
UMC/LDB/FEM-2 was switched on after ZMU switch ZMU or WMU off and on again
or WMU
CLM-2 motor unit was connected after switch off ZMU or WMU and UMC/LDB/FEM-2,
switching on ZMU and/or WMU switch on again and
recalibrate the system
Motor LED flashes red Several motor units are set to the same operational switch off, set selector switch on each motor
function or plugged into the UMC/LDB/FEM-2. unit CLM-1 to the corresponding function,
The READY LEDs on the manual control units or plug CLM-2 motor units into the
also flash red corresponding position. Switch on.
CLM-2 motor unit defective replace CLM-2 motor unit