184
Trouble-Shooting
Problem Cause Remedy
7.4 WMU Wireless Main Unit LEDs
WMU cannot be switched on During calibration no extra WMU can be swiched on wait until calibration is finished
READY-LED flashes red Incorrect cable configuration switch off, set selector switch on motor units CLM-1
to correct position, or attach motor unit CLM-2
to the correct socket on the UMC/LDB/FEM-2, or turn
selector switch on the WFU to the corresponding function,
switch on
READY-LED illuminated red Operating error on a control unit reset to original setting, switch off,
(e.g.selector for radio channel was changed) check settings on control unit, switch on
Use of a locked control element, perform all functions in proper sequence
e.g. SET key while camera is running
UMC/LDB/FEM-2 is switched off switch on UMC/LDB/FEM-2, switch WMU off and on
UMC/LDB/FEM-2 was switched on after WMU switch WMU off and on
operational unit was removed while the system was on switch WMU off and on
READY-LED flashes red/green WMU-3/WBU-3/-4 communication lost exchange WMU-3/WBU-3/-4. Work can also be continued.