Instruction manual
192
Trouble-Shooting
Problem  Cause  Remedy
READY LED flashes green/red  The OPEN or CLOSE button has been pressed  avoid operational errors 
  while the motor was at an end position 
  Calculated F-Stop is outside of the range  iris compensation not possible 
  of the iris ring
CAL LED flashes  End stops are invalid  calibrate 
  Iris ring has been turned while the ICU  recalibrate 
  was switched off 
  and then been driven to an end-stop. 
  Iris ring moves with difficulty  Clean or readjust 
  or is stuck/gears may mesh too tightly
BAT illuminated red  Battery voltage low  change battery, do not start a new take 
BAT red flashing  Battery voltage very low  change battery immediately 
    danger of deeply discharging the batty 
    do not start a new take