Instruction manual

192
Trouble-Shooting
Problem Cause Remedy
READY LED flashes green/red The OPEN or CLOSE button has been pressed avoid operational errors
while the motor was at an end position
Calculated F-Stop is outside of the range iris compensation not possible
of the iris ring
CAL LED flashes End stops are invalid calibrate
Iris ring has been turned while the ICU recalibrate
was switched off
and then been driven to an end-stop.
Iris ring moves with difficulty Clean or readjust
or is stuck/gears may mesh too tightly
BAT illuminated red Battery voltage low change battery, do not start a new take
BAT red flashing Battery voltage very low change battery immediately
danger of deeply discharging the batty
do not start a new take