Instruction manual
58
Mounting the CLM-2 with /without a console
Order number of the console: K2.52035.0
• Flip up the locking lever ➪ photo and screw back the
ballcatch ➪ photo with a screwdriver until it disappears
completely in the bracket.
• Push the tube ➪ photo flush into the console receptacle,
taking care that the slit in the tube points towards the
ballcatch.
• Screw the ballcatch out of the bracket until the tube
can no longer be pushed out of the bracket.
• Turn the locking lever until a slight resistance can be
felt, then press the lever downwards.
• Fasten the motor unit CLM-2 to the console tube.
locking lever tube
receptacle
ballcatch
Setup