Instruction manual
69
4.2 Attaching and Connecting the Manual Control Units
After cabling up the motors and their power supplies, it is
necessary to define which manual control units will be used
to control the motors. The selection can be made using the
diagram on ➪ the fold-out page in the back of this
manual. In the squares is listed which units and cables are
necessary for the desired application.
Connect the cables listed in the diagram with the different
units according to the following table:
To cable the cable manual control units
Code Description Connection between Length / m Plug with no. pins
LC-Z1 Zoom cable ZMU / CLM-1 3.5 Fischer 5 Fischer 5
LC-F1 Focus cable ZMU or FIU-1 / FIU-1 2 Fischer 10 Fischer 10
LC-F2 Focus cable ZMU or FIU-1 / FIU-1 0.2 Fischer 10 Fischer 10
WC-W1 WHA-1 with WRC-1 WHA-1 with WRC-1 / 16 SR3, 535, 2 Fischer 8 Fischer 16
435, 435ES, 435 Adv. with FEM-1
LC-M1 WHA-2/3 LCS Cable WHA-2/3 / LDB, RCS, 435 Adv+FEM-2 1 Fischer 5 Fischer 5
LC-Z1 WHA-2/3 LCS Cable WHA-2/3 / LDB, RCS, 435 Adv+FEM-2 3,5 Fischer 5 Fischer 5
KC 70 WHA-2/3 CAC Cable ARRICAM ST/LT WHA-2/3 3 Fischer 16 Fischer 5
Note: The focus iris unit FIU-1 cannot be used together
with a WFU-1 or WFU-3 in radio operation
since these units cover the same functions.
Note: The zoom cable LC-Z1 can be extended by 75 m
with the cable drum LC-E1.
Setup