Instruction manual
81
Note: The camera (ARRICAM with LDB or ARRIFLEX
435 Xtreme/Advanced with FEM-2) or the UMC
must always be switched on prior to the WMU.
• Switch on the power supply with the ON key ➪ photo
on the WMU.
Note: If the ARRICAM with LDB, the ARRIFLEX 435
Xtreme/Advanced with FEM-2 or the UMC is
switched off while radio contact exists, all connected
WMUs will also be automatically switched off.
The READY LEDs on the WMU ➪ photo and the motor
unit CLM-1 or the universal motor controller UMC will
briefly illuminate red. Then the Ready LED on the WMU-1
will show the status of the LCS:
green LCS is ready for operation
red operating error on one unit (e.g. incorrect key pressed,
WMU switched on before UMC)
flashing red the selector switch on the motor unit is incorrectly set
or connected to the incorrect socket on the UMC
Note: The LEDs on the CLM-1 or UMC, LDB or FEM-2
flash green when the lens reaches the end of the
set operating range.
Operation
READY-LED
READY-LED
main switch WMU-3 main switch WMU-1/-2