User's Manual
Table Of Contents
- Contents
- Introduction
- Installing the i3822V (Outside Unit)
- Installing the iPSU (Power Supply Unit)
- Verifying the i3822V and iPSU Installations
- Installing the i38HG (Inside Unit)
- Troubleshooting
- Checking DSL links
- Checking the i3822V wiring
- Checking i3822V ports
- Checking i3822V LED status
- Verifying broadband operation and statistics
- Testing cables
- Performing an HPNA test
- Isolating HPNA issues
- Verifying voice services
- Verifying the iPSU connection
- Verifying the backup battery operation
- Bypassing i3822V electronics
- Regulatory Information
- Technical Specifications
- Index
Chapter 3 Installing the iPSU (Power Supply Unit) 27
Connecting the power cables
After the iPSU is mounted, connect the following three sets of cables to begin
supplying power to the i3822V:
• The power line between the iPSU and i3822V
• The AC power cord to the AC outlet
• The battery cable
Connecting the power supply to the i3822V
To connect the iPSU unit to the i3822V:
1. Use a Phillips screwdriver to unfasten the screw securing the power terminal
cover.
2. Insert the end of the power cable from the i3822V through the round opening on
the right panel of the iPSU.
3. Strip 3/8” to 5/8” on the power cable pair to expose the wires.
4. Connect the color-coded wires that correspond to the color-coded binding posts of
the power terminals to the outside unit.
Note: Make sure to maintain polarity: red is positive, black is negative. If the wires
are reversed, the i3822V will not power up.
5. Place the cover back on the power supply post and make sure that it is properly
seated.
Note: Do not pinch the wires.
6. Fasten the screw to secure the power terminal cover.
POWER
SILENCE ALARM
BATTERY
C
AUTION
POTENTIAL SHOCK
Power terminal cover
Opening