User's Manual

Installation & User Manual
Fault Reporting
The unit has an open collector output than can relay any fault
condition to an external device. This uses the third pin in the power
connector. This pin is rated at 12V, 200mA and is at ground potential
when a fault condition exists.
Figure 2 Power Connector Pinout
Operation
The in-building repeater operates automatically and does not
require user intervention. There are no user controls, except for a
sliding switch to allow a user to connect additional subscriber
antenna on the repeaters secondary port to increase coverage area.
The front panel has two LEDs. A green ‘Power’ LED indicates that
the repeater is operating. The ‘Status’ LED indicates several
conditions; consult the troubleshooting section for details.
Product
Maintenance
The CR300 does not require maintenance, as long as it is properly
installed following the guidelines stated in this manual. It is
recommended that all RF connectors be periodically checked for
corrosion, strain relief. Also periodically check the integrity of power
connections
Copyright © 2004 Arrista Technologies Inc. All rights reserved.
7