VENDETTA 4X4 3S Manual

WWW.ARRMA-RC.COM
ESC LED INDICATOR
LED Indicator LED Code
ESC turned On, LED Throttle trigger is in the
neutral zone
Red LED illuminated
ESC is operating in
forward throttle
Red and Green LED
illuminated
ESC is at full throttle,
full brake or full reverse
short single pulses
LVC protection
activated
short single pulses
The ESC is in thermal
short pulses repeating
The ESC has exceeded the
continuous current limit
short pulses repeating
The ESC has failed the
self test
short pulses repeating
Capacitor temp has
been exceeded
TROUBLESHOOTING GUIDE
Problem and LED Indi-
cator
Error Mode Possible Causes Solution
Motor won’t operate. LED
single pulses.
LVC has been
activated.
Battery voltage is
below the LVC setting.
Verify the battery is charged.
Motor won’t operate.
short single pulses.
The ESC is in
mode.
The ESC is taking too
much load.
cool before resuming operation.
Consider making changes to gear
ratio to reduce load to the ESC.
Motor won’t operate. LED
pulses repeating.
The ESC has
failed the self test.
The ESC is damaged.
Send the ESC to a Horizon Hobby
service center for service.
Motor won’t operate. LED
short pulses repeating.
Capacitor
temp has been
exceeded
There is too much load
on the drive system for
the ESC to support.
Consider changing the battery or
gearing to reduce the load on the ESC,
or change your driving habits to reduce
the load.
No throttle or steering on
with single short pulse
repeating.
N/A
Throttle trim not at
neutral.
on transmitter to neutral. Turn
back on.
19