Specifications

MAINTENANCE
550 Gas/LPG 330650 (8--01)
62
SRS SOLUTION TANK
The tank has a capacity of 265 gal (1000 L).
When the tank is full, a ball float will rise and shut
off the vacuum to the tank. A 72 in (1830 mm)
long drain hose for the recovery tank is located on
the front of the tank. You can determine the water
level in the tank by lowering the hose end until
water appears--this will then be the water level in
the tank, (engine must be off; this stops vacuum).
To drain the tank, lower the hose and place in
suitable floor drain.
Empty and clean the solution tank and flush the
laminar tubes after every shift.
W ARNING: Flammable Materials Can
Cause Explosion Or Fire. Do Not Use
Flammable Materials In Tanks.
Partially fill the solution tank with clean water . Run
the SRS pump for a few minutes to flush the
solution hoses.
NOTE: The water must not be hotter than 130_F
(54_C) or tank damage may occur.
B
A
00343
DRAINING SOLUTION TANK
A. Drain Hose
B. Clean-out Door
Six clean-out doors are provided on the tank: two
at the front, two at the upper rear , and two at the
lower rear of the tank. Using the sludge removal
tool, remove all sand, sludge, debris, etc., from
the tank. Remove the two large plugs above the
tank tires near the upper front of the tank. Flush
the sediment from all compartments of the tank
and the wire mesh filters. Check for dirt buildup in
the laminar flow tubes. To clean tubes, remove
and flush. Also, check the return hoses and
connections for clogging or damage.
A
C
B
00345
REMOVING LAMINAR TUBES
A. Solution Outlet Filter
B. Laminar Tube Set Fastener
C. Upper Rear Clean-Out Door
A
B
00342
REMOVING LAMINAR TUBES
A. Laminar Tube Set
B. Upper Rear Clean-Out Door
NOTE: Keep laminar tube sections facing the
outside of the machine.