Specifications
4-2  OPERATION  CHAPTER 4 
DT-203X, DT-105X and DT-110X display series 
4.3.1. Modify parameters 
To go into modify parameters menu, you should push the advance pushbutton for more 
than three seconds, labelled with «*». After the 3 seconds, the display shows the first parameter 
in flashing mode.  
From this point, there are two options: 
1- Display the parameters value. 
By pushing advance (“*”) you may see the parameters value. The increase pushbutton, 
labelled «+», lets you modify the parameter. 
To select the parameters name push the advance pushbutton («*»). 
2- Select another parameter. 
While the  parameter  name  is  flashing,  every  time  you  push  the  increase  pushbutton 
(«+») you select a new parameter. 
4.3.2. Exit modify parameters 
To exit the  modify parameters menu, select the  parameter «END» and  then push 
advance «*». 
4.3.3. Meaning of each parameter. 
4.3.3.1. Parameter 1: Language. 
The  language  menu.  There are  four  languages  available:  Catalan,  Spanish,  French 
and English. 
4.3.3.2. Parameter 2: Address 
The  network  display  address.  Selectable  between  0  and  299.  Depends  on  each 
protocol. 
4.3.3.3. Parameter 3: Protocol 
The selected protocol. The protocols available are TDL, Modbus, Omron, ASCII and 
S7-200. 
4.3.3.4. Parameter 4: Baud Rate 
Selects  the  transmission  baud  rate.  There are  two  baud  rates  available: 9600  and 
19200. 
4.3.3.5. Parameter 5: Data length 
Selects the transmission data length. Select 7 o 8 bits. 
4.3.3.6. Parameter 6:Parity 
Selects the transmission parity. Select Even, Odd or None. 