Specifications
CHAPTER 3
INSTALLATION
3-1
DT-203X, DT-105X and DT-110X display series
3. INSTALLATION
The installation of the DT-203X, DT-105X and DT-110X, is not particularly delicate, but
some important considerations must be taken into account.
It must not be anchored to places subject to vibrations, nor should it be installed in
places which generally surpass the limits specified in the display characteristics, both in terms of
temperature and humidity.
The degree of protection of displays DT-203X, DT-105X and DT-110X is IP41, meaning
that they are protected against penetration by solid foreign objects of a diameter of about 1mm
and against the vertical fall of water droplets.
Displays DT-203X, DT-105X and DT-110X, should not be installed in places with
illumination level higher than 1000 lux. Neither should the display be placed in direct sunlight as
visibility would be lost.
In the electrical installation, proximity to lines of high intensity circulation and high
voltage lines must be avoided, as well as proximity to High Frequency generators and U/F
converters for motors.
3.1. Power supply.
The power supply must be 88 to 264 VAC 47 to 63Hz.
The power supply conductor section will be in line with consumption and the ground
conductor will be a minimum section of 1.5mm².
Although the displays are specially prepared for environments with high levels of
electrical noise, should you suspect that the power supply line is very noisy, we advise a
separating transformer be connected between the supply line and the display and/or an exterior
network filter be connected. The power supply connector has 3 contacts and is situated in the
lower part of the unit. Connect the power wires following the schema below
1
3
2
1- 230V
2- 230V
3- GND