The ART CX310 may be used in a wide variety of applications and environments. Enclosed in a 1U 
(1.75 inches high) rack-mountable, all-steel enclosure, the unit is designed for continuous 
professional use. The depth is 6.5 inches, exclusive of the power cord. Mounting location is not 
critical. However, for greater reliability, we recommend that you not place the unit on top of power 
amps or other sources of heat. 
AC POWER HOOKUP 
The CX310 has an internal power supply designed to operate from 105 to 120VAC at 50/60Hz. 
Export units are configured with a different power cord and the voltage switch is set for the country of 
destination. Before plugging the CX310 into the AC mains, make sure that all of the equipment 
following the crossover outputs are turned off or that all of the outputs are turned down. 
INPUT/OUTPUT CONNECTIONS 
The CX310 has XLR and 1/4" TRS phone jack connectors for each input and output. All connections 
are active balanced although the 1/4" phone jack connections can easily be converted to unbalanced 
operation by using two-conductor phone plugs. Inserting a plug into a 1/4" jack disconnects the 
associated XLR connector. 
MONO 3-WAY CONFIGURATION 
This information is intended to clarify how the CX310 is used in the mono 3-way configuration. 
Connections: 
Input   Channel One INPUT 
  (Channel Two INPUT not used) 
Low Output    Channel One LOW OUTPUT 
Mid Output    Channel Two LOW OUTPUT 
High Output    Channel Two HIGH OUTPUT 
        (Channel One HIGH OUTPUT not used) 
Controls: 
Input Level    Channel One INPUT LEVEL control 
Low Output Mute  Channel One LOW MUTE switch 
Low Output Level  Channel One LOW OUTPUT LEVEL control 
Low/Mid Crossover  Channel One RANGE switch and FREQUENCY control 
        (Channel One HIGH MUTE switch and 
         HIGH OUTPUT LEVEL control not used) 
        (Channel Two INPUT LEVEL control not used) 
Mid Output Mute  Channel Two LOW MUTE switch 
Mid Output Level  Channel Two LOW OUTPUT LEVEL control 
Mid/High Crossover  Channel Two RANGE switch and FREQUENCY control 
High Output Mute  Channel Two HIGH MUTE switch 
High Output Level  Channel Two HIGH OUTPUT LEVEL control 