4. Compare the two sets of blocks,
5. Restore the initial data blocks if
Safe was selected,
6. Select a new set of blocks and go back to step 1.
Notes:
MDR User Guide 43
The <StartBlock> parameter must be lower than the <LastBlock> parameter,
If the <LastBlock> parameter is omitted then the MDR tests only the
<StartBlock> block on the disks.
set-state
Syntax:
set-state <State>
Description: Set the state of current recording.
The new state is given by the <State> argument. This argument can be set to
STORED (the current recording stays or becomes stored) or NOTSTORED (the current
recording stays or becomes not stored).
Example:
set-state STORED
set-state NOTSTORED
set-start-block
Syntax:
set-start-block <BlockNo>
Description: Set the start block of current recording.
The start block is given by the
<BlockNo> argument.
Example: set-start-block 400
Use caution when executing the set-start-block command as the recording may be
inadvertently deleted. To avoid this when using the
set-start-block command,
always execute the commands for recording in the following sequence:
new-recording 10
set-start-block <BlockNo>
record
show-recording-table
Syntax:
show-recording-table
Description: Show the MDR recording table.
The
show command displays the recorder information of the MDR recording table.
The
show command prints out the following information:
Recorder info:
Total capacity : 67.8 GiB ( 17365 blocks)
Capacity used : 0.0 B ( 0 blocks)
Capacity available : 67.8 GiB ( 17365 blocks)
Largest recording size : 67.8 GiB ( 17365 blocks)
Recorder block size : 4.0 MiB
Number of recordings : 0 (maximum : 895)