Specifications

MDR User Guide  73 
Severity level: 
Low  Modify the behavior of the program/operating system without 
major consequences, 
Medium   Item which can modify the program/operating system with 
important consequences, 
High  Item which have very high consequences on the behavior of 
the related program/operating system. 
10.2 Item modification 
An item can be modified in one of the configuration files using the MIDAS Monitor 
functions  mgf or iset. For further information on the use of the mgf function, see 
section 7.7 Configuring an MDR Unit by preloading the Boot Parameter Files. 
The 
iset command can be used as follows: 
Following the board's self-test, the MDR unit will present a short countdown to 
permit you to enter the MIDAS monitor: 
Press any key to interrupt the countdown and then press the Enter key 2 or 3 times 
within 2 seconds (to perform autobaud). The MIDAS monitor prompt # should then 
appear. 
Update an item with the 
iset command: 
#iset <section> <item> <text> <file> 
For instance, to change the number of disks used (to 8) by the MDR system, type in 
the MIDAS Monitor: 
#iset StorageInfo Disks 8 mdr.ini 
Exit the monitor with the quit command: 
#quit 
The MDR unit will reboot. This time, allow the countdown to expire and the MDR 
firmware will begin executing. 
For more information on the 
iset command, please see the MIDAS Monitor online help 
(help command under the MIDAS Monitor). 
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com