Specifications

MDR User Guide 77
The values of StartInputWaitTime and InputWaitTime, divided by 60, represent
the number of seconds the MDR server will wait before stopping the current record
operation (if there isn’t any input stream).
This mode enables a user-defined watchdog timer for the DPIO data input stream: if
there is no data for a period of time then the MDR server assumes that the end of
recording has been reached. It will then stop the recording in progress and the DPIO
input module, set up the new recording size (according to the number of blocks
received) and return to the MDR host software with an error message. If no data at all
is received then the recording size is set to the
RecordingBlockSize value.
OutputWaitTime
Maximum time the MDR server will wait between two consecutive recorder blocks
while playing back data. The value of this item could be considered as the maximum
time the data stream can use to transfer a block of data from the recorder (its size is
the RecorderBlockSize value). If this item is missing or set to –1 then the MDR
server will wait forever during the playback and never return, provided that the
receiver never receive the data (the watchdog timer is disabled in this case).
As for
StartInputWaitTime and InputWaitTime, OutputWaitTime, divided by 60,
represent the number of seconds the MDR server will wait before stopping the
current playback operation.
ByteSwap
Enables (if set to
Enable) or disables (if set to Disable) the byte swapping. If this
item is missing, then the byte swapping is disabled.
OutputFreqDivisor
Output oscillator frequency divisor. This item specified the value by which the
frequency of the oscillator frequency (on an DPIO output module only) is divided.
The allowed values for this item are 0, 2, 4 and 8. If this item is set to any other value
or is missing then the default value (0) is used.
WaitForSync
Enables (if set to
Enable) or disables (if set to Disable) the wait for SYNC
functionality of the DPIO device. If this item is missing then the SYNC signal is not
used (Wait for sync functionality is disabled).
PeclStrobe
Enables (if set to
Enable) or disables (if set to Disable) the PECL strobe
functionality of the DPIO device. If this item is missing then the PECL strobe is
disabled.
InputStartSignal
Select the start signal the data source is triggered on when starting a record operation.
The PIO1 (resp. PIO2) signal is used if this item is set to
PIO1 (resp. PIO2). The
value Disable is used to disable this feature: in this case, the MDR do not trigger the
data source.
If this item is missing then the PIO1 signal is used by the MDR to trigger the data
source.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com