86  MDR User Guide 
B Error Messages 
Error Name 
Error 
Number
Error Message  Error Description 
S_mdr_COMMBUF_TOO_SMALL 0x55500001 
The TCP/IP 
communication 
buffer is too 
small. 
The MDR Server or the MDR Client is trying to send, 
through the communication buffer, a buffer larger than 
the communication buffer size. 
S_mdr_COMM_OUT_OF_SYNCH 0x55500002 
Communication 
out of synchroni-
zation. 
The MDR Client has received a response packet that 
doesn’t match the expected response to the command 
sent previously to the MDR Server. 
S_mdr_COMM_INTERFACE_DOWN 0x55500003 
Communication 
interface down. 
The communication interface is down 
S_mdr_CURRENT_RECORDING_NOT_SET 0x55500004 
The current re-
cording is not set. 
There is no recording present in the recording table and 
the MDR software expects the current recording to be 
set. 
S_mdr_DISK_ALREADY_IN_USE 0x55500005 
Disk already in 
use 
The disk is already included in a disk group. It cannot 
be included in two different disk groups at the same 
time. 
S_mdr_DISK_ERROR 0x55500006 
MDR disk error.  The MDR Server is unable to write to the storage de-
vice. 
S_mdr_DISK_GROUP_NOT_FOUND 0x55500007 
Disk group not 
found 
The disk group cannot be found. The disk group name 
may be invalid or some disks contained in the disk 
group may be missing or unreachable. 
S_mdr_DISK_GROUP_ALREADY_PRESENT 0x55500008 
Disk group al-
ready present 
The disk group with the same name is already present 
on the FC loops. 
S_mdr_DPIO_EEPROM_DAMAGED 0x55500009 
DPIO EEPROM 
damaged 
The EEPROM of the DPIO is damaged. 
S_mdr_DPIO_ERROR 0x5550000A 
DPIO ERROR  DPIO error. 
S_mdr_DPIO_NOT_PRESENT 0x5550000B 
DPIO not present.  DPIO module is not installed in the MDR System and 
the MDR Server has received a command that requires 
the use of this DPIO module. 
S_mdr_DPIO_OVERFLOW 0x5550000C 
Overflow in FIFO 
of DPIO device. 
The data source is sending data faster than what the 
DPIO input module is able to transfer. If the data path is 
FPDP and the data source supports the Suspend signal, 
then the configuration item SuspendEnable (section 
DpioInfo in the configuration file mdr.ini) should be 
set to 1 (i.e. enabled). 
S_mdr_ILLEGAL_OPERATION 0x5550000D 
Illegal operation.  The current state does not allow the command. This 
error is reported, for instance, when the MDR is re-
cording and receives in the same time another command 
that involves a modification of the recording table. 
S_mdr_INVALID_ARGUMENT 0x5550000E 
Invalid argument.  At least one argument of the command is not valid. 
S_mdr_INVALID_MEMORY_BLK_TBL 0x5550000F 
Invalid Memory 
Block Table. 
The MDR Memory Block Table has not been initialized 
correctly. 
S_mdr_INVALID_MODEL_NAME 0x55500010 
Invalid MDR 
model name. 
The MDR model name specified in the configuration 
file mdr.ini is not valid. 
S_mdr_INVALID_PARAMETER 0x55500011 
Invalid parameter.  An MDR Server / MDR API / MDR Shell function 
parameter is not valid. 
S_mdr_INVALID_RECORDER_BLK_TAG 0x55500012 
Invalid recorder 
block tag 
The tag present inside the data of the recorder block is 
invalid. 
S_mdr_INVALID_RECORDING_NUMBER 0x55500013 
Invalid recording 
number. 
The recording number specified is not valid. The re-
cording number must be a positive number, not null, 
and lower or equal to the number of the last recording 
present in the recording table. 
S_mdr_INVALID_RECORDING_STATE 0x55500014 
Invalid recording 
state 
The state of the recording is invalid. For instance, the 
MDR Shell copy disks host ./ 1 is executed 
whereas the recording number 1 is not stored. 
S_mdr_INVALID_USER_BLKSIZE 0x55500015 
Invalid user block 
size. 
Reserved for future use. 
S_mdr_MDR_INI_FILE_ERROR 0x55500016 
MDR ini file 
error. 
The MDR Server / MDR API / MDR Shell is unable to 
read an item (or its value) from the configuration file 
mdr.ini. 
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com