Specifications
192-040011 N18
COMPAX 4500S / COMPAX 8500S
Automation
10
Parker Hannifin GmbH
Electromechanical Division
COMPAX 45XXS/85XXS
Connector assignment
X11X9
Input
Output Output
Input
Test Control
X10
X6
X8
RS232
Ready Error
ENTER+-
Value
Status Number
X9 test
X12 resolver
X16 absolute
X14 HEDA
X18 reserved
X11 Control
X6 RS232
output 
motor
X17 initiators
X13 encoder
DIGI TAL
X15 HEDA
X8 digital input
 / output
X10 digital input
 / output
ext. supply
Plan view COMPAX 45XXS / 85XXS
HV
T
D
L1
L2
L3
AC 
supply
Ballast
resistor
X5 RS485 IN
X7 RS485 OUT
R
D
X2
Connexion
PE 10mm
2
Installation and dimensions
395
DIGI TAL
24
378
351
77
125
65
275
325
11
65
Output data for individual units
Device
COMPAX ..
Nominal cur-
rent [Aeff]
Peak current
[Aeff] <5s
Power
[kVA]
at mains supply: 400V AC
45XXS 6.5 13.0 4.5
85XXS 12.5 25.0 8.6
at mains supply: 460V AC
45XXS 5.4 13.0 4.5
85XXS 10.5 25.0 8.6
Power supply (limit values)
• 3*80V AC - 3*500V AC; 45-65Hz.
Typical AC mains: 400V ±10%; 460V ±10%; 480V ±5%.
Regeneration mode
• Storable energy:
COMPAX 45XXS: 330µF / 52Ws
COMPAX 85XXS: 500µF/80 Ws
• Internal ballast resistor: 300W continuous/3kW for
<1s (20s cooling time).
• External ballast resistance: 22Ω/450W
For the external ballast resistors available, please
refer to page 16.
Fastening: 4 M5 Allen screws
Installation distance: 135mm