Specifications

192-040011 N18
COMPAX 3500M
Automation
13
Parker Hannifin GmbH
Electromechanical Division
COMPAX 35XXM
Connector assignment
Digital
COMPAX-M
X5 X7
IN OUT
X19
Control
H1
X6
Inp ut
Output
Status
Value
+-
Enter
Ready
Error
RS 232
Test
Control
X8 X10
X9 X11
Number
X13
Encoder
X9 Test
X6 RS232
X7 OUT
X5 IN
Bus
systems:
X19
Control
X8/X10 In-/
Output
X11 Control
X14/X15
HEDA
X17 Initiators
X16 Absolute
encoder
X12
Resolver
Plan view
L1 L2 L3
PE
PE
PE
+
-
U
VW
PE
+
-
F1
Mains Input
DC - In
Braking
Motor
Motor
X 20
24 V
X 21
Resistance
X 22 X 1
Brake
X 23
Motor
Spannungs-
versorgung
bis 500V AC
24V Steuer-
spannung
externer
Ballast-
widerstand
Motor-
Bremse
F1
3.16A
Output data
Unit
COMPAX ..
Nominal cur-
rent [Aeff]
Peak current
[Aeff] <5s
Power
[kVA]
at mains supply: 400V AC
35XXM 50.0 100.0 35.0
at mains supply: 460V AC
35XXM 42.0 100.0 35.0
Voltage supply range
3 x 250V – 3 x 500V AC; 45 - 65 Hz.
Typical AC mains: 400V ±10%;
460V ±10%; 480V ±5%
Other COMPAX-M controllers can be linked se-
quentially up to a rating of 15KW.
Mains supply fuse protection
62A K circuit breaker or suitable Neozed conventional
fuse.
Regeneration mode
Storable energy: 3450µF/542 Ws
External ballast resistance: 10 / 2kW
For external ballast resistors, refer to page 16.
Installation / dimensions
Fastening: 4 M6 Allen screws
390
340
86
65 65
218
190
450
363
190
430
10
14
38
Digital
COMPAX-M
X5 X7
IN OUT
X19
Control
H1
X6
Input
Output
Status
Value
+-Enter
Ready Er ror
RS 232
Test
Control
X8 X10
X9 X11
Number
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com