Specifications
192-040011 N18
EMC measures
Automation
15
Parker Hannifin GmbH
Electromechanical Division
EMC measures
AC surge filter
The following input filters may be used for RF suppression and/or for compliance with
the emission limit values as specified by EN61800-3.
Type: NFI01/02
Type: NFI01/03
Dimension diagram:
6,6
A
B
C
D
E
F
G
Ø 4
L
I
N
E
L
O
A
D
Type: NFI01/04
307
61
152
337
320
35
6.5
M5
25
400
347
Line
Netzseite
Load
Lastseite
10mm
2
COMPAX 35XXM with sequentially mounted COMPAX-M controllers: Type: NFI01/05
LINE
LOAD
110 ±0.3
150 max.
325 ±1
M10
17Nm
6,5 x 15
301 max.
378 max.
81 max.
15
42
58
NMD10 / COMPAX
45XXS / 85XXS
COMPAX 1000SL:
(COMPAX 1000SL motor
cable > 50m
NMD20:
COMPAX 35XXM:
NFI01/02 NFI01/03
A 177 240
B 151 217
C 70±0.3 115±0.3
D 140 159
E 125 145±0.5
F 111 129
G65 64