Specifications

192-040011 N18
AC surge filter / motor output filter
Automation
16
Parker Hannifin GmbH
Electromechanical Division
COMPAX 25XXS: motor cable >10m
COMPAX 10XXSL: motor cable <50m
COMPAX 25XXS: motor cable
10m
NFI01/01 Dimension diagram: NFI01/06 Dimension diagram:
50,8±0,3
85,4
116
139
79,5
101
88,9±0,4
55,5
Ø 4
5,2 x 4
L
I
N
E
L
O
A
D
66 max.
91 max.
51 max.
75 ±0.3
5,3
L
N
FASTON
6,3 x 0,8
L'
N'
LINE
LOAD
27
12
32 max.
3,5
20
Unshielded: <0.5m
Shielded: <5m
Motor output filter
We supply motor output filters for use with long motor leads (greater than 20m)
Type: MDR01/01 16A / 2mH
Type: MDR01/02 30A / 1.1mH
Type: MDR01/03 >30A / 0.64mH
COMPAX 1000SL,
COMPAX 25XXS:
Length of connec-
tion between input
filter and unit:
Up to 16A nomi-
nal motor current:
Up to 30A nomi-
nal motor current:
Over 30A nominal
motor current:
MDR01/01 MDR01/02 MDR01/03
A [mm] 150 180 205
B [mm] 67 76 107
D [mm] 113 136 157
E [mm] 50 57 83
F [mm] 6 6 7
H [mm] 195 195 260
I [mm] 95 110 150
Weight [kg] 4 6 17
A
B
I
F
D
E
H
U1 V1 W1 + - U2 V2 W2 + -