Specifications

192-040011 N18
Electronic cam control
Automation
24
Parker Hannifin GmbH
Electromechanical Division
CamEditor for creating curves
All the 2500 available data records in the reference point memory may be assigned to a single profile or to a
number of profiles. Each reference point can generate an auxiliary function signal using the 8 digital and 2 ana-
logue outputs.
Creating profiles
You can use the HAUSER CamEditor to create cam
profiles. This is a Windows program and provides the
advantages of a Windows interface.
Profile input and creating the reference point ta-
ble
You specify the fixed points which are essential to
the profile. The CamEditor takes these and uses an
interpolation process to create intermediate points
which reflect the required profile. The result is dis-
played in graphic form as a position, speed and ac-
celeration plot.
CamEditor may be used to assign auxiliary functions
to any reference point.
Fixpoints
set point table
for COMPAX
1. set point
2. set point
max. 2500
set points
Calculation of
the set points
with the PC
Master Slave
0
º
120
º
130
º
140
º
0mm
10mm
15mm
17mm
145
º
18mm
Menu for fixed point entry
Menu for auxiliary function entry
Linear cam diagram
Polar cam diagram
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com