Specifications

192-040011 N18
Technical data
Automation
27
Parker Hannifin GmbH
Electromechanical Division
Bus connection options
All with opto-isolated bus link.
RS485
Max. 115k Baud 2 or 4 wire/RS485
Interbus S
2-conductor remote bus 500 kBaud.
max. 64 participants per ring.
Profibus
1.5M Baud Sinec L2-DP and FMS.
CS31
COMPAX - ABB interface.
CANbus
Up to 1.0MBaud Basic CAN.
CAN protocol in acc. with specification 1.2.
Hardware in acc. with ISO/DIS 11898
CANopen
Protocol in acc. with CiA DS 301.
Profile CiA DS 402 for drives.
Operation
Parameter input/status request
Via COMPAX hand-held terminal.
Via RS232 and bus interface.
Via the programmable controller data interface (not
for COMPAX 1000SL).
Status query also via the 3-digit LED display on the
front plate (not for COMPAX 1000SL).
Housing
Housing
Fully-enclosed metal housing.
Insulation: VDE 0160/protection class IP20.
IP54 on request.
Connections
Motor, power bus, control inputs & outputs via ter-
minals.
Sensor cables & interfaces via two-part connectors.
Installation
Panel-mounting, suitable for installation in industrial
control cabinets.
Dimensions
NMD/COMPAX-M: refer to page 11.
COMPAX 25XXS: refer to page 9.
COMPAX 10XXSL: refer to page 8.
COMPAX 45XXS/85XXS: refer to page 10.
Weights: COMPAX P1XXM:............. 5.6 kg
COMPAX 10XXS: ............. 1.6 kg
COMPAX 25XXSL: ........... 4.6 kg
COMPAX 45XXS/85XXS: . 6.5 kg
COMPAX 02XX: ................ 7.1 kg
COMPAX 05/15:................ 7.8 kg
COMPAX 35XXM: ........... 22.5 kg
NMD10: ............................. 7.6 kg
NMD20: ............................. 8.1 kg
Standard scope of supply
COMPAX with User Guide.
X8, X9, X10, X11 mating connectors.
ServoManager.
Mains power module
For technical data, please refer to page 12.
Permissible 3-phase mains power
supplies
The units (COMPAX or NMD) can be operated on all
mains configurations
1
. Examples:
IT mains power supplies
TN mains power supplies
1
When using Delta mains power sup-
plies, note that CE requirements (low
voltage guideline) are no longer satis-
fied when the voltage between a
phase and earth >300V AC (isolated
measurement voltage).
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com