Specifications

192-040011 N18
COMPAX 1000SL
Automation
8
Parker Hannifin GmbH
Electromechanical Division
COMPAX - family
Housing technology:
The housing and heat sink are designed to prevent the following 3 major problems occurring in the servo drive
and control system.
The fully-enclosed metal housing provides shielding against electromagnetic interference
The generously proportioned heat sink prevents overheating and increases service life
Large surface contact with the rear panel provides good high frequency grounding
COMPAX 1000SL
Connector assignment
Fieldbus In
Encoder
Input / Output
Resolver
Fieldbus Out
Limit Switch
24 V DC
R
Dump
H2
H1
RS232
X6X5X13
X12
X17
X19
X2
X1 X4 X3
X14 X15
HEDA Out HEDA In
Input
+-
L1 N PE
UV
W
PE + -
Motor
Brake
PE
+
-
230 V AC
COMPAX - SL
X7
X13
Encoder
X6 RS232
X7 OUT
X5 IN
Bus-
systems:
X19 Input/
Output
X14/X15
HEDA
X17
Initiators
X12
Resolver
X3 24V DC
Voltage suppply
X4 Ballast-
resistor
X1 Motor and
motor brake
X2 230V AC
Voltage supply
Connection PE -
Output data
Device
COMPAX ..
Nominal cur-
rent [Aeff]
Peak current
[Aeff] <5s
Power
[kVA]
10XXSL 2.5 5 1
Power supply (limit values)
1*100V AC-1*250V AC; 45-65Hz
Typical AC mains: 230V ±10%
Regeneration mode
Storable energy: 660µF/17Ws
External ballast resistance: 100 / 60W continuous /
253W for >1s (10s cooling period)
For external ballast resistors, refer to page 16.
Installation and dimensions
Fieldbus InEncoder
Input / Output
Resolver
Fieldbus Out
Limit Switch
24 V DC
R
Dump
H2
H1
RS232
X6X5X13
X12
X17
X19
X2
X1 X4 X3
X14
X15
HEDA Out HEDA In
Input
+-
L1 N PE
UV
W
PE + -
Motor
Brake
PE
230 V AC
85
180
206,5
145,5
197,5
16
5
55
174
+
-
COMPAX - SL
183
X7
Fastening: 3 M4 Allen screws
Installation distance: 100mm
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com