Specifications
192-040011 N18
COMPAX 1000SL
Automation
8
Parker Hannifin GmbH
Electromechanical Division
COMPAX - family
Housing technology:
The housing and heat sink are designed to prevent the following 3 major problems occurring in the servo drive
and control system.
♦ The fully-enclosed metal housing provides shielding against electromagnetic interference
♦ The generously proportioned heat sink prevents overheating and increases service life
♦ Large surface contact with the rear panel provides good high frequency grounding
COMPAX 1000SL
Connector assignment
Fieldbus In
Encoder
Input / Output
Resolver
Fieldbus Out
Limit Switch
24 V DC
R
Dump
H2
H1
RS232
X6X5X13
X12
X17
X19
X2
X1 X4 X3
X14 X15
HEDA Out HEDA In
Input
+-
L1 N PE
UV
W
PE + -
Motor
Brake
PE
+
-
230 V AC
COMPAX - SL
X7
X13
Encoder
X6 RS232
X7 OUT
X5 IN
Bus-
systems:
X19 Input/
Output
X14/X15
HEDA
X17
Initiators
X12
Resolver
X3 24V DC
Voltage suppply
X4 Ballast-
resistor
X1 Motor and
motor brake
X2 230V AC
Voltage supply
Connection PE -
Output data
Device
COMPAX ..
Nominal cur-
rent [Aeff]
Peak current
[Aeff] <5s
Power
[kVA]
10XXSL 2.5 5 1
Power supply (limit values)
• 1*100V AC-1*250V AC; 45-65Hz
Typical AC mains: 230V ±10%
Regeneration mode
• Storable energy: 660µF/17Ws
• External ballast resistance: 100Ω / 60W continuous /
253W for >1s (10s cooling period)
For external ballast resistors, refer to page 16.
Installation and dimensions
Fieldbus InEncoder
Input / Output
Resolver
Fieldbus Out
Limit Switch
24 V DC
R
Dump
H2
H1
RS232
X6X5X13
X12
X17
X19
X2
X1 X4 X3
X14
X15
HEDA Out HEDA In
Input
+-
L1 N PE
UV
W
PE + -
Motor
Brake
PE
230 V AC
85
180
206,5
145,5
197,5
16
5
55
174
+
-
COMPAX - SL
183
X7
Fastening: 3 M4 Allen screws
Installation distance: 100mm
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com