5.7.6.  E-508.00 Gain Polarity and Output Range Settings 
  NOTICE 
Damage from electrostatics! 
The E-500/E-501 system contains electrostatic sensitive devices (EGB) and can be damaged 
if handled improperly. 
  Avoid touching components, pins and PCB tracks. 
  Before touching an electronic component, discharge yourself of any electric charges: 
−  While working, wear an antistatic wrist strap  
or 
−  Briefly touch a conducting, grounded object. 
Making the gain polarity switch and output range jumper accessible 
Only remove modules from the chassis when you are authorized and have the 
corresponding qualifications. 
1.  Remove the E-500/E-501 system from the power source by pulling the power plug. 
2.  Wait a minute to be sure that any residual voltage has dissipated.  
3.  Remove the E-508.00 module from the chassis: 
a)  Loosen the four Phillips screws on the front panel. 
b)  Using the grip at the bottom of the front panel, pull the module out of the chassis. 
4.  To access settings for gain polarity and output range, remove the rear cover plate from the E-
508.00 module and slide back the perforated aluminum top. 
Perforated Al top 
Rear cover plate 
Trim Pots: DO NOT TOUCH 
Gain polarity switch 
Left: 
gain = 
-100  
Right (default): 
g
ain = +100 
Setting the Gain Polarity Switch 
It is important to understand the relation between gain and the Control In range. 
With DC-offset = 0 (full CCW), the Control In range is equal to output range (as set below) 
divided by the gain. 